Duration of a temporal extent expressed as a number scaled by a temporal unit.<br/>
Element Source Role Target Role
RbcProperties
Class  
Name: stopInShuntingSuppTimer
 
Name:  
 
Details:
As long as this timer is running, the train can ignore  "stop if in shunting" message. <br/>
AtbLoop
Class  
Name: hasSwitchOffTimer
 
Name:  
 
Details:
The timer during which the loop stays active. Timer starts at activation.<br/>
EulynxPropertySet
Class  
Name: hasConTMaxSmiConnection
 
Name:  
 
Details:
Con_tmax_SMI_Connection.<br/>When MDM fails to connect to the field element subsystem within this delay, the IL tries to connect. Default is 20 s.<br/>
CentralControlledAreaDepartureTrack
Class  
Name: hasTimerValue
 
Name:  
 
Details:
 
AutomaticRouteSettingSystem
Class  
Name: hasCancellationDuration
 
Name:  
 
Details:
The duration after which the ARS system stops trying to call routes.<br/>de-DE: Zeit bis zum Lenkabbruch, wenn die zyklische Stellbarkeitsprüfung der ZL bis dahin negativ war. <br/>
LevelCrossingSignalRelation
Class  
Name: hasTimeToTrackCrossing
 
Name:  
 
Details:
Stores the driving time to the track crossing.<br/>
LogicalInputChannel
Class  
Name: hasSwitchOnMessageDelay
 
Name:  
 
Details:
Con_t_Message_Delay_Time - on.<br/>The delay after which the acquired change of input value false to true is reported, in the range between 0 and 2047 ms.<br/>
EulynxPropertySet
Class  
Name: hasConTMaxDataInstallation
 
Name:  
 
Details:
Con_tmax_DataInstallation<br/>Timer that starts counting after completion of data upload from MDM to the EULYNX field element subsystem, default is 60s.<br/>
DurationOfSunshine
Class  
Name: quantity
 
Name:  
 
Details:
 
LevelCrossingActivationDelaySet
Class  
Name: hasSupplierSpecificActivationDelay
 
Name:  
 
Details:
The activation delay depends on the level crossing system supplier and may differ from the calculated delay. <br/>Both calculated and supplier values must be stored.<br/>
AxleCountingSectionConfiguration
Class  
Name: hasMinFcpOrFcpa
 
Name:  
 
Details:
Con_t_Min_FC_P_or_FC_P_A<br/>Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep.<br/>- Proposed resolution: steps of 0,5 s<br/>- Proposed range: from 0 s up to 3600 s<br/><br/>
ControllerRelation
Class  
Name: hasCon_tmax_PDI_Connection
 
Name:  
 
Details:
Con_tmax_PDI_Connection<br/>Time-out value for creating the PDI connection to the field element controller, by default 20 seconds.<br/>
EtcsOverlap
Class  
Name: hasOverlapTimer
 
Name:  
 
Details:
The overlap timer T_OL. If not given, overlap has infinite validity.<br/>
AxleCountingSectionConfiguration
Class  
Name: hasDelayOfNotificationOfAvailability
 
Name:  
 
Details:
Con_t_Delay_Of_Notification_Of_Availability<br/>Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem -<br/>Electronic Interlocking, following the state change of a TVPS from occupied to vacant<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 0 s up to 10 s<br/><br/>
EulynxPropertySet
Class  
Name: hasConTMaxResponseMdm
 
Name:  
 
Details:
Con_tmax_Response_MDM.<br/>When the MDM doesn't perform any action on the controller within this delay, try connect to the IL. Default is 10s.<br/>
HybridLevel3Timers
Class  
Name: muteTime
 
Name:  
 
Details:
Time starts counting down each time information is received from the train. After expiry the train is considered mute. This allows recovery from a short communication gap. <br/>Paragraph 3.4.1.2<br/>
ActiveAspect
Class  
Name: hasTimedDeactivation
 
Name:  
 
Details:
Describes a delay after which the aspect disappears.<br/>
MovableElementConfiguration
Class  
Name: hasMaxOperationDuration
 
Name:  
 
Details:
Con_tmax_Point_Operation, the maximum time during which the object controller shall try to drive the movable element. <br/>This parameter is mostly given by generic rules but can be configurable.<br/>The timer starts with the command Moving to the Point machines and defines the max. time span after the Point has to arrive to an End position. After that time span the command Moving to the Point machines is set to Stop moving.<br/>resolution: steps of 100 ms.<br/>range: Between 100 ms and 30 s<br/><br/>
LogicalOutputChannel
Class  
Name: hasSwitchOnActivationDelay
 
Name:  
 
Details:
Con_t_Activation_Delay - on<br/>The delay after which the output is activated, in the range 0 to 2047 ms.<br/>
HL3SectionTimers
Class  
Name: shadowTrainTime
 
Name:  
 
Details:
Time starts counting when the trackside has ascertained that there can't be a shadow train in the wake of a HL3 train. <br/>Paragraph 3.4.1.4 <br/>
AutomaticRouteSettingSystem
Class  
Name: checksForOpenSignalAfterRouteCall
 
Name:  
 
Details:
The delay between the route call and the check that the signal has opened.<br/>de-DE: Prüfung auf Fahrtstellung Signal nach Anstoß innerhalb einer Zeit, bei Nicht-Fahrtstellung Lenkabbruch, Angabe in Sekunden, Standard 120 s. Der gewählte Wert muss größer sein als die Summe aus Anstoßverzögerung und Fahrstraßenbildungszeit.<br/>
PresignProperties
Class  
Name: timeNeededForRegulation
 
Name:  
 
Details:
The time needed for switching the road traffic light installation.<br/>de-DE: Nur bei BUESTRA: Zeitbedarf für die Beeinflussung des Straßenverkehrs (Parameter tK1 gemäß Ril 815.0051).<br/>
EulynxPropertySet
Class  
Name: hasConTMaxDataTransmission
 
Name:  
 
Details:
Con_tmax_DataTransmission<br/>Maximum duration of data transmission. Retry when timer expires, default is 300s.<br/>
AxleCountingSectionConfiguration
Class  
Name: hasMaxFcpOrFcpa
 
Name:  
 
Details:
Con_t_Max_FC_P_or_FC_P_A<br/>The maximum delay between detecting a sweeping train and confirmation of a successful sweeping.<br/>- Proposed resolution: steps of 1 s<br/>- Proposed range: from 0 s up to 7200 s<br/><br/>
PzbSpeedCheckingSystemProperties
Class  
Name: triggerDeactivationDelay
 
Name:  
 
Details:
The trigger device is deactivated after a given delay that depends on the checked speed. <br/><br/>de-DE: Prüfzeit der GÜ<br/>
ArsRouteTrigger
Class  
Name: hasAdditionalTime
 
Name:  
 
Details:
A duration that makes the trigger apply earlier for special design situations.<br/>de-DE: Zeitzuschlag für die Berechnung des Anstoßpunktes der ZL. Es kann sich die Notwendigkeit ergeben, eine Zeitspanne auf die bisher errechneten Zeiten (Sichtzeit Vorsignal, Fahrstraßenbildungszeit ...) aufzuschlagen, damit der ZL-Anstoß früher erfolgt, als nach der allgemeinen Berechnungsregel vorgesehen. <br/>
LevelCrossingClearanceDetectionSystem
Class  
Name: startsAfterClosingProcess
 
Name:  
 
Details:
The time interval from activation of the level crossing to the moment the barriers are fully closed. The detection system starts after the latter moment. <br/>Only given when relevant. NR doesn't use this because determined by rule.<br/>de-DE: BÜ-Sicherungszeit.<br/>
SignalSightingDistance
Class  
Name: hasSupplementaryResponseTime
 
Name:  
 
Details:
The supplementary response time for the train driver to interpret the signal information in seconds.<br/>
StandstillDetectionForShunting
Class  
Name: hasStandstillTimer
 
Name:  
 
Details:
 
CombiningTrack
Class  
Name: usesTimer
 
Name:  
 
Details:
Duration, after which the first train is most likely to stand still.<br/>Nil when irrelevant.<br/>
RouteApproachLocking
Class  
Name: hasDelayedRelease
 
Name:  
 
Details:
Delay between the route cancellation request and the release of the route. <br/>The delay ensures that the route remains locked until it is certain that the approaching train has stopped or can stop short of the entry signal.<br/>This class does not specify whether release is automatic or manual. This is derived amongst others from the type of signal to which the locking applies.<br/>
TrainDescriberAcoustic
Class  
Name: hasUnspecifiedAlarmDuration
 
Name:  
 
Details:
Duration of the alarm sound accompanying the train display field.<br/>de-DE: Dauer einer akustischen Meldung im ZN Anzeigefeld. <br/>
TrainDescriberAcoustic
Class  
Name: hasPreAlarmDuration
 
Name:  
 
Details:
Duration of acoustic warning in the pre-announcement field.<br/>de-DE: Dauer einer akustischen Meldung im Voranzeigefeld.<br/>
RbcProperties
Class  
Name: hasPermShuntTimer
 
Name:  
 
Details:
Permission to shunt timer. When the driver hasn't started the shunting process before, the permission to shunt is revoked.<br/>
TriggerAssignmentWithDelay
Class  
Name: hasDelay
 
Name:  
 
Details:
The signal clearing/closing is delayed by this value.<br/>
HL3SectionTimers
Class  
Name: ghostTrainPropagationTime
 
Name:  
 
Details:
Timer starts counting when a TTD section becomes unexpectedly occupied so that "ghost" rolling stock is assumed present. <br/>Paragraph 4.2.2.1<br/>
VirtualSubSection
Class  
Name: integrityLossPropagationTime
 
Name:  
 
Details:
Time after which the train's loss-of-integrity propagates. Starts counting when trackside detects loss-of-integrity.<br/>After expiry, occupancy spills over to adjacent sections. <br/>
LocalOperationDevice
Class  
Name: hasBuzzerSoundingDuration
 
Name:  
 
Details:
de-DE: Hupdauer in Sekunden<br/>
TrainDescriberDisplayField
Class  
Name: hasDeletionDelay
 
Name:  
 
Details:
The delay after which the train identity is deleted. Only used in case of manual deletion. Given in seconds.<br/>de-DE: Verzögerungszeit, bis die Löschung der Zugnummer erfolgt. Die Angabe ist bei manueller Zugnummernlöschung notwendig. <br/>
LevelCrossingController
Class  
Name: hasClosureTime
 
Name:  
 
Details:
Timer for supervising the delay between level crossing activation and confirmation of closure. Given in seconds, in the range 0 to 1800 sec.<br/>If the timer isn't informed, a EULYNX controller does not supervise the closure time. <br/>
CssPropertySet
Class  
Name: usesRestartTimer
 
Name:  
 
Details:
The restart timer is the delay needed before CSS may be safely restarted after the system went down.<br/>
RbcWatchdog
Class  
Name: hasLifeSignTimer
 
Name:  
 
Details:
Duration of the heart beat.<br/>
OverlapRelease
Class  
Name: hasOverlapReleaseDelay
 
Name:  
 
Details:
Time that expires before the interlocking releases the overlap.<br/>
ArsRoute
Class  
Name: hasDistantSignalSightingTime
 
Name:  
 
Details:
The driving time between the moment the driver sees the signal and the moment the signal opens.<br/>DB: 15 s <br/>NR: not used.<br/>
LevelCrossingActivationDelaySet
Class  
Name: hasCalculatedActivationDelay
 
Name:  
 
Details:
Calculated delay of level crossing activation for optimal barriers-closed time. The delay runs from the moment of detection to the moment the activation is requested.<br/>Can be zero, i.e. immediate activation.<br/>
RouteExit
Class  
Name: hasResidualRouteReleaseTimer
 
Name:  
 
Details:
Timer for release of a residual route.<br/>nl-NL: Restrijweg Vrijmaken (RV)<br/>De RV timer is bepaald aan hand van alle routes en de langste sectie naar het eindsein. Deze tijd wordt dan toegepast op elke rijweg naar het eindsein.<br/>
HybridLevel3Timers
Class  
Name: waitIntegrityTime
 
Name:  
 
Details:
Timer start counting when the trackside has ascertained train integrity from the train report. <br/>Paragraph 3.4.1.3<br/>
LevelCrossingActivationDelaySet
Class  
Name: hasSupplierSpecificSignalDelay
 
Name:  
 
Details:
The opening of the main signal covering the level crossing can be delayed. <br/>Typically, in case of half-barrier crossings, this allows road users to evacuate the danger area. <br/>This value is adapted to supplier-specific level crossing time behaviour.<br/>
LevelCrossingTimerSet
Class  
Name: hasLeadTimer
 
Name:  
 
Details:
Lead timer that activates the level crossing earlier.<br/>de-DE: BÜ Vorlaufzeit<br/>
DoubleLogicalInputChannel
Class  
Name: hasSwitchingPeriod
 
Name:  
 
Details:
Con_tmax_Switching_Period<br/>The time in milliseconds during which violation of antivalence or equivalence condition is tolerated, in the range between 0 and 255 ms<br/><br/>
EulynxPropertySet
Class  
Name: hasConTMaxNoMaintenance
 
Name:  
 
Details:
Con_tmax_No_Maintenance is the maximum duration after which a field element controller that doesn't use the MDM and that received a maintenance release request from the IL, is again available for a PDI connection. In the range 1-30s, with default value 10 seconds.<br/>
LevelCrossingTimerSet
Class  
Name: hasAdditionalTimer
 
Name:  
 
Details:
de-DE: Nachlaufzeit<br/>
RouteConvergencyConflict
Class  
Name: hasDurationForCheck
 
Name:  
 
Details:
The train is supposed to have stopped when the associated section is proven to have been occupied for at least this amount of time. Otherwise the train is supposed in approach and the conflicting route is kept closed.<br/>
VirtualSubSection
Class  
Name: disconnectPropagationTime
 
Name:  
 
Details:
Time between mute and start of propagation of the unknown occupancy status.<br/><br/>
RbcProperties
Class  
Name: hasGeneralMessageTimer
 
Name:  
 
Details:
Time interval between general messages from RBC to train. This checks that the train is still communicating with the RBC.<br/>
LogicalInputChannel
Class  
Name: hasSwitchOffMessageDelay
 
Name:  
 
Details:
Con_t_Message_Delay_Time - off.<br/>The delay after which the acquired change of input value true to false is reported, in the range between 0 and 2047 ms.<br/>
SelfSupervisedLevelCrossingSystem
Class  
Name: hasTimeOut
 
Name:  
 
Details:
Timer starts when train is announced and reports time-out after the given duration.<br/>de-DE: Zeitüberschreitungsmeldung.<br/>
LevelCrossingController
Class  
Name: hasPdiLossDeactivationTimer
 
Name:  
 
Details:
The duration between a activation caused by an interrupted Safe communication protocol (PDI) connection and a deactivation of the Level Crossing protection facility.<br/>When not informed, a EULYNX controller does not implement this function.<br/>
CssPropertySet
Class  
Name: usesAxleCounterResetTimer
 
Name:  
 
Details:
the maximum time that the CSS waits, after giving a reset command to an axle counter, for the release of this axle counter. If no release is received within the specified time, the CSS will regard this as an unsuccessful reset.<br/>
AutomaticRouteSettingSystem
Class  
Name: hasStaffReactionDuration
 
Name:  
 
Details:
The delay within which staff is supposed to react/acknowledge.<br/>de-DE: Personalreaktionszeit, Angabe in Sekunden. Der Standardwert auf Hauptbahnen beträgt 45 Sekunden, der Standardwert auf Nebenbahnen 15 Sekunden. Abweichungen sind möglich, bedürfen jedoch der betrieblichen Bestätigung.<br/>
EtcsAcknowledgement
Class  
Name: hasAckDuration
 
Name:  
 
Details:
The <i><u>designed </u></i>duration during which the transition acknowledgement is requested. Given this duration this value, one computes the L_ACKLEVELTR or L_ACKMAMODE.<br/>
LevelCrossingActivationDelaySet
Class  
Name: hasCalculatedSignalDelay
 
Name:  
 
Details:
The opening of the main signal covering the level crossing can be delayed. If not provided, equals zero.<br/>Typically allows road users to evacuate the danger area in case of half-barrier crossings.<br/><br/>
RouteSetupTime
Class  
Name: hasSetupTime
 
Name:  
 
Details:
 
ArsSpeedCategory
Class  
Name: hasTriggerDelay
 
Name:  
 
Details:
The ARS trigger for this speed category is delayed by the given duration. Typically 0 for the fastest category.<br/>de-DE: Verzögerungszeit für den ZL-Anstoß. Ist keine tv erforderlich, ist 0 anzugeben.<br/>
AxleCountingSectionConfiguration
Class  
Name: hasInhibitionTimer
 
Name:  
 
Details:
Con_t_Inhibition_Timer<br/>The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable.<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 100 ms up to 10 s<br/>
RouteApproachLocking
Class  
Name: hasDelayedLock
 
Name:  
 
Details:
Delay between the moment the approach section turns from vacant to occupied and the moment the interlocking locks the route.<br/>
RbcProperties
Class  
Name: hasAckTimer
 
Name:  
 
Details:
RBC acknowledgement timer: A configurable timer used to resend application messages in case of communication loss. The timer starts at the moment of sending the application message for which acknowledgement is required.<br/>
LogicalInputChannel
Class  
Name: hasDebounceTime
 
Name:  
 
Details:
Debounce time in milliseconds, in the between 0 and 255 ms.<br/><br/>
TunnelSignalTimer
Class  
Name: closesSignalWithDelay
 
Name:  
 
Details:
The delay after which a tunnel entry signal is closed.<br/>
SimpleTimeInterval
Class  
Name: hasDuration
 
Name:  
 
Details:
Allows defining a "floating" time interval, i.e. not anchored to a start or end moment in time.<br/>
LevelCrossingActivationDelaySet
Class  
Name: hasDefaultPartialTimer
 
Name:  
 
Details:
de-DE: TeilvorgabeZeit<br/>
SignalMessageRelation
Class  
Name: hasEndSectionTimer
 
Name:  
 
Details:
The end-section of a route is the section between the closed route exit signal and the previous worker signal. <br/>The interlocking revokes (part of) the route when this timer expires.<br/>
LogicalOutputChannel
Class  
Name: hasSwitchOffActivationDelay
 
Name:  
 
Details:
Con_t_Activation_Delay - off<br/>The delay after which the output is deactivated, in the range 0 to 2047 ms.<br/><br/>
Tag Value
iri <a href="http://www.w3.org/2006/time#Duration" target="_blank" >http://www.w3.org/2006/time#Duration</a>
Details:
 
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
AR-0111 - Sighting time distant signal Requirement Dependency From  
RbcProperties Class Strong To As long as this timer is running, the train can ignore "stop if in shunting" message.
AtbLoop Class Strong To The timer during which the loop stays active. Timer starts at activation.
Eu.TDS.1215 Requirement Realization To  
EulynxPropertySet Class Strong To Con_tmax_SMI_Connection. When MDM fails to connect to the field element subsystem within this delay, the IL tries to connect. Default is 20 s.
CentralControlledAreaDepartureTrack Class Strong To  
AutomaticRouteSettingSystem Class Strong To The duration after which the ARS system stops trying to call routes. de-DE: Zeit bis zum Lenkabbruch, wenn die zyklische Stellbarkeitsprüfung der ZL bis dahin negativ war.
LevelCrossingSignalRelation Class Strong To Stores the driving time to the track crossing.
LogicalInputChannel Class Strong To Con_t_Message_Delay_Time - on. The delay after which the acquired change of input value false to true is reported, in the range between 0 and 2047 ms.
EulynxPropertySet Class Strong To Con_tmax_DataInstallation Timer that starts counting after completion of data upload from MDM to the EULYNX field element subsystem, default is 60s.
DurationOfSunshine Class Strong To  
AR-0720 - ARS route addition Requirement Dependency From  
Eu.Gen.4250 Requirement Realization To  
LevelCrossingActivationDelaySet Class Strong To The activation delay depends on the level crossing system supplier and may differ from the calculated delay. Both calculated and supplier values must be stored.
AxleCountingSectionConfiguration Class Strong To Con_t_Min_FC_P_or_FC_P_A Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep. - Proposed resolution: steps of 0,5 s - Proposed range: from 0 s up to 3600 s
Eu.LC.175 Requirement Realization To  
LC-1902 - Duration of closing process Requirement Dependency From  
LC-0603 - Timeout announcement Requirement Dependency From  
Eu.TDS.1212 Requirement Realization To  
Eu.IO.1288 Requirement Realization To  
ControllerRelation Class Strong To Con_tmax_PDI_Connection Time-out value for creating the PDI connection to the field element controller, by default 20 seconds.
EtcsOverlap Class Strong To The overlap timer T_OL. If not given, overlap has infinite validity.
Eu.TDS.1214 Requirement Realization To  
AxleCountingSectionConfiguration Class Strong To Con_t_Delay_Of_Notification_Of_Availability Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem - Electronic Interlocking, following the state change of a TVPS from occupied to vacant - Proposed resolution: steps of 100 ms - Proposed range: from 0 s up to 10 s
EulynxPropertySet Class Strong To Con_tmax_Response_MDM. When the MDM doesn't perform any action on the controller within this delay, try connect to the IL. Default is 10s.
HybridLevel3Timers Class Strong To Time starts counting down each time information is received from the train. After expiry the train is considered mute. This allows recovery from a short communication gap. Paragraph 3.4.1.2
Eu.IO.1282 Requirement Realization To  
ActiveAspect Class Strong To Describes a delay after which the aspect disappears.
MovableElementConfiguration Class Strong To Con_tmax_Point_Operation, the maximum time during which the object controller shall try to drive the movable element. This parameter is mostly given by generic rules but can be configurable. The timer starts with the command Moving to the Point machines and defines the max. time span after the Point has to arrive to an End position. After that time span the command Moving to the Point machines is set to Stop moving. resolution: steps of 100 ms. range: Between 100 ms and 30 s
LogicalOutputChannel Class Strong To Con_t_Activation_Delay - on The delay after which the output is activated, in the range 0 to 2047 ms.
HL3SectionTimers Class Strong To Time starts counting when the trackside has ascertained that there can't be a shadow train in the wake of a HL3 train. Paragraph 3.4.1.4
LC-0103 - activation delay calculated Requirement Dependency From  
AutomaticRouteSettingSystem Class Strong To The delay between the route call and the check that the signal has opened. de-DE: Prüfung auf Fahrtstellung Signal nach Anstoß innerhalb einer Zeit, bei Nicht-Fahrtstellung Lenkabbruch, Angabe in Sekunden, Standard 120 s. Der gewählte Wert muss größer sein als die Summe aus Anstoßverzögerung und Fahrstraßenbildungszeit.
PresignProperties Class Strong To The time needed for switching the road traffic light installation. de-DE: Nur bei BUESTRA: Zeitbedarf für die Beeinflussung des Straßenverkehrs (Parameter tK1 gemäß Ril 815.0051).
EulynxPropertySet Class Strong To Con_tmax_DataTransmission Maximum duration of data transmission. Retry when timer expires, default is 300s.
AxleCountingSectionConfiguration Class Strong To Con_t_Max_FC_P_or_FC_P_A The maximum delay between detecting a sweeping train and confirmation of a successful sweeping. - Proposed resolution: steps of 1 s - Proposed range: from 0 s up to 7200 s
PzbSpeedCheckingSystemProperties Class Strong To The trigger device is deactivated after a given delay that depends on the checked speed. de-DE: Prüfzeit der GÜ
ArsRouteTrigger Class Strong To A duration that makes the trigger apply earlier for special design situations. de-DE: Zeitzuschlag für die Berechnung des Anstoßpunktes der ZL. Es kann sich die Notwendigkeit ergeben, eine Zeitspanne auf die bisher errechneten Zeiten (Sichtzeit Vorsignal, Fahrstraßenbildungszeit ...) aufzuschlagen, damit der ZL-Anstoß früher erfolgt, als nach der allgemeinen Berechnungsregel vorgesehen.
RO-0507 - Delayed release Requirement Dependency From  
TS-0103 - Acoustics duration other Requirement Dependency From  
Eu.LC.1321 Requirement Realization To  
LevelCrossingClearanceDetectionSystem Class Strong To The time interval from activation of the level crossing to the moment the barriers are fully closed. The detection system starts after the latter moment. Only given when relevant. NR doesn't use this because determined by rule. de-DE: BÜ-Sicherungszeit.
Eu.LC.177 Requirement Realization To  
SignalSightingDistance Class Strong To The supplementary response time for the train driver to interpret the signal information in seconds.
StandstillDetectionForShunting Class Strong To  
CombiningTrack Class Strong To Duration, after which the first train is most likely to stand still. Nil when irrelevant.
RouteApproachLocking Class Strong To Delay between the route cancellation request and the release of the route. The delay ensures that the route remains locked until it is certain that the approaching train has stopped or can stop short of the entry signal. This class does not specify whether release is automatic or manual. This is derived amongst others from the type of signal to which the locking applies.
TrainDescriberAcoustic Class Strong To Duration of the alarm sound accompanying the train display field. de-DE: Dauer einer akustischen Meldung im ZN Anzeigefeld.
OP-0203 - Buzzer turn-on time Requirement Dependency From  
TrainDescriberAcoustic Class Strong To Duration of acoustic warning in the pre-announcement field. de-DE: Dauer einer akustischen Meldung im Voranzeigefeld.
RbcProperties Class Strong To Permission to shunt timer. When the driver hasn't started the shunting process before, the permission to shunt is revoked.
TriggerAssignmentWithDelay Class Strong To The signal clearing/closing is delayed by this value.
HL3SectionTimers Class Strong To Timer starts counting when a TTD section becomes unexpectedly occupied so that "ghost" rolling stock is assumed present. Paragraph 4.2.2.1
VirtualSubSection Class Strong To Time after which the train's loss-of-integrity propagates. Starts counting when trackside detects loss-of-integrity. After expiry, occupancy spills over to adjacent sections.
Eu.IO.1287 Requirement Realization To  
LocalOperationDevice Class Strong To de-DE: Hupdauer in Sekunden
TrainDescriberDisplayField Class Strong To The delay after which the train identity is deleted. Only used in case of manual deletion. Given in seconds. de-DE: Verzögerungszeit, bis die Löschung der Zugnummer erfolgt. Die Angabe ist bei manueller Zugnummernlöschung notwendig.
TS-0104 - Acoustics duration advance display field Requirement Dependency From  
LevelCrossingController Class Strong To Timer for supervising the delay between level crossing activation and confirmation of closure. Given in seconds, in the range 0 to 1800 sec. If the timer isn't informed, a EULYNX controller does not supervise the closure time.
CssPropertySet Class Strong To The restart timer is the delay needed before CSS may be safely restarted after the system went down.
RbcWatchdog Class Strong To Duration of the heart beat.
OverlapRelease Class Strong To Time that expires before the interlocking releases the overlap.
LC-0107 - Signal delay chosen Requirement Dependency From  
Eu.TDS.1213 Requirement Realization To  
RO-0905 - Route setting completion time Requirement Dependency From  
NumericQuantity Class Generalization To  
AR-0707 - Trigger delay for speed class Requirement Dependency From  
ArsRoute Class Strong To The driving time between the moment the driver sees the signal and the moment the signal opens. DB: 15 s NR: not used.
LevelCrossingActivationDelaySet Class Strong To Calculated delay of level crossing activation for optimal barriers-closed time. The delay runs from the moment of detection to the moment the activation is requested. Can be zero, i.e. immediate activation.
LC-0117 - Presetting time Requirement Dependency From  
LC-2325 - Impact road traffic Requirement Dependency From  
LC-0610 - LC closed time train approaching Requirement Dependency From  
RouteExit Class Strong To Timer for release of a residual route. nl-NL: Restrijweg Vrijmaken (RV) De RV timer is bepaald aan hand van alle routes en de langste sectie naar het eindsein. Deze tijd wordt dan toegepast op elke rijweg naar het eindsein.
HybridLevel3Timers Class Strong To Timer start counting when the trackside has ascertained train integrity from the train report. Paragraph 3.4.1.3
LevelCrossingActivationDelaySet Class Strong To The opening of the main signal covering the level crossing can be delayed. Typically, in case of half-barrier crossings, this allows road users to evacuate the danger area. This value is adapted to supplier-specific level crossing time behaviour.
Eu.IO.7612 Requirement Realization To  
LevelCrossingTimerSet Class Strong To Lead timer that activates the level crossing earlier. de-DE: BÜ Vorlaufzeit
DoubleLogicalInputChannel Class Strong To Con_tmax_Switching_Period The time in milliseconds during which violation of antivalence or equivalence condition is tolerated, in the range between 0 and 255 ms
EulynxPropertySet Class Strong To Con_tmax_No_Maintenance is the maximum duration after which a field element controller that doesn't use the MDM and that received a maintenance release request from the IL, is again available for a PDI connection. In the range 1-30s, with default value 10 seconds.
LevelCrossingTimerSet Class Strong To de-DE: Nachlaufzeit
RouteConvergencyConflict Class Strong To The train is supposed to have stopped when the associated section is proven to have been occupied for at least this amount of time. Otherwise the train is supposed in approach and the conflicting route is kept closed.
LC-0104 - activation delay chosen Requirement Dependency From  
VirtualSubSection Class Strong To Time between mute and start of propagation of the unknown occupancy status.
RbcProperties Class Strong To Time interval between general messages from RBC to train. This checks that the train is still communicating with the RBC.
AR-0110 - Setting operating time Requirement Dependency From  
LogicalInputChannel Class Strong To Con_t_Message_Delay_Time - off. The delay after which the acquired change of input value true to false is reported, in the range between 0 and 2047 ms.
SelfSupervisedLevelCrossingSystem Class Strong To Timer starts when train is announced and reports time-out after the given duration. de-DE: Zeitüberschreitungsmeldung.
LevelCrossingController Class Strong To The duration between a activation caused by an interrupted Safe communication protocol (PDI) connection and a deactivation of the Level Crossing protection facility. When not informed, a EULYNX controller does not implement this function.
CssPropertySet Class Strong To the maximum time that the CSS waits, after giving a reset command to an axle counter, for the release of this axle counter. If no release is received within the specified time, the CSS will regard this as an unsuccessful reset.
AutomaticRouteSettingSystem Class Strong To The delay within which staff is supposed to react/acknowledge. de-DE: Personalreaktionszeit, Angabe in Sekunden. Der Standardwert auf Hauptbahnen beträgt 45 Sekunden, der Standardwert auf Nebenbahnen 15 Sekunden. Abweichungen sind möglich, bedürfen jedoch der betrieblichen Bestätigung.
TS-0311 - Manual delay deletion Requirement Dependency From  
EtcsAcknowledgement Class Strong To The designed duration during which the transition acknowledgement is requested. Given this duration this value, one computes the L_ACKLEVELTR or L_ACKMAMODE.
RO-2001 - ReleaseDelay Requirement Dependency From  
LevelCrossingActivationDelaySet Class Strong To The opening of the main signal covering the level crossing can be delayed. If not provided, equals zero. Typically allows road users to evacuate the danger area in case of half-barrier crossings.
RouteSetupTime Class Strong To  
TP-0834 - Checking time Requirement Dependency From  
AR-0108 - Cancellation time Requirement Dependency From  
ArsSpeedCategory Class Strong To The ARS trigger for this speed category is delayed by the given duration. Typically 0 for the fastest category. de-DE: Verzögerungszeit für den ZL-Anstoß. Ist keine tv erforderlich, ist 0 anzugeben.
Eu.IO.1281 Requirement Realization To  
AxleCountingSectionConfiguration Class Strong To Con_t_Inhibition_Timer The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable. - Proposed resolution: steps of 100 ms - Proposed range: from 100 ms up to 10 s
LC-0106 - Signal delay calculated Requirement Dependency From  
RouteApproachLocking Class Strong To Delay between the moment the approach section turns from vacant to occupied and the moment the interlocking locks the route.
LC-0611 - LC delay time second train Requirement Dependency From  
RbcProperties Class Strong To RBC acknowledgement timer: A configurable timer used to resend application messages in case of communication loss. The timer starts at the moment of sending the application message for which acknowledgement is required.
LogicalInputChannel Class Strong To Debounce time in milliseconds, in the between 0 and 255 ms.
Eu.LC.1323 Requirement Realization To  
TunnelSignalTimer Class Strong To The delay after which a tunnel entry signal is closed.
SimpleTimeInterval Class Strong To Allows defining a "floating" time interval, i.e. not anchored to a start or end moment in time.
LevelCrossingActivationDelaySet Class Strong To de-DE: TeilvorgabeZeit
SignalMessageRelation Class Strong To The end-section of a route is the section between the closed route exit signal and the previous worker signal. The interlocking revokes (part of) the route when this timer expires.
AR-0112 - Staff reaction time Requirement Dependency From  
LogicalOutputChannel Class Strong To Con_t_Activation_Delay - off The delay after which the output is deactivated, in the range 0 to 2047 ms.