A set of properties that apply to an axle counting section that is controlled by a EULYNX SCI-TDS.<br/>
Attribute
Private boolean
  acceptsDrfc_Il
Details:
Notes: True: the TVPS accepts the DRFC command from the interlocking. <br/>False: the TVPS is configured not to accept the DRFC command from the interlocking.<br/>Irrelevant if the value isn't provisioned.<br/><br/>
Private boolean
  acceptsDrfc_m
Details:
Notes: True: the TVPS accepts the DRFC command from the maintainer.<br/>False: the TVPS is configured not to accept the DRFC command from the maintainer.<br/>Irrelevant if the value isn't provisioned.<br/><br/>
Private boolean
  acceptsUfl
Details:
Notes: True: the TVPS can execute the UFL command .<br/>False: the TVPS isn't configured to execute the UFL command.<br/>Irrelevant if the value isn't provisioned.<br/>
Private boolean
  variantA_B
Details:
Notes: True: variant A<br/>False: variant B.<br/>In variant A, this TVPS accepts FC-C after expiration of the inhibition timer when operationally disturbed and the last detected passing is an incoming axle or an unreliable pattern. <br/>In variant B, this TVPS doesn’t accept FC-C after expiration of the inhibition timer when operationally disturbed and the last detected passing is an incoming axle or an unreliable pattern.<br/><br/><br/><br/>
Element Source Role Target Role
Duration
Class  
Name: hasInhibitionTimer
 
Name:  
 
Details:
Con_t_Inhibition_Timer<br/>The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable.<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 100 ms up to 10 s<br/>
Duration
Class  
Name: hasMaxFcpOrFcpa
 
Name:  
 
Details:
Con_t_Max_FC_P_or_FC_P_A<br/>The maximum delay between detecting a sweeping train and confirmation of a successful sweeping.<br/>- Proposed resolution: steps of 1 s<br/>- Proposed range: from 0 s up to 7200 s<br/><br/>
Duration
Class  
Name: hasDelayOfNotificationOfAvailability
 
Name:  
 
Details:
Con_t_Delay_Of_Notification_Of_Availability<br/>Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem -<br/>Electronic Interlocking, following the state change of a TVPS from occupied to vacant<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 0 s up to 10 s<br/><br/>
Duration
Class  
Name: hasMinFcpOrFcpa
 
Name:  
 
Details:
Con_t_Min_FC_P_or_FC_P_A<br/>Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep.<br/>- Proposed resolution: steps of 0,5 s<br/>- Proposed range: from 0 s up to 3600 s<br/><br/>
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
Eu.TDS.1215 Requirement Realization To  
Eu.TDS.7037 Requirement Realization To  
Eu.TDS.7037 Requirement Realization To  
Duration Class Strong From Con_t_Inhibition_Timer The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable. - Proposed resolution: steps of 100 ms - Proposed range: from 100 ms up to 10 s
Eu.TDS.1212 Requirement Realization To  
TdsSectionConfiguration Class Generalization To  
Eu.TDS.7039 Requirement Realization To  
Eu.TDS.1214 Requirement Realization To  
Eu.TDS.1213 Requirement Realization To  
Duration Class Strong From Con_t_Max_FC_P_or_FC_P_A The maximum delay between detecting a sweeping train and confirmation of a successful sweeping. - Proposed resolution: steps of 1 s - Proposed range: from 0 s up to 7200 s
Duration Class Strong From Con_t_Delay_Of_Notification_Of_Availability Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem - Electronic Interlocking, following the state change of a TVPS from occupied to vacant - Proposed resolution: steps of 100 ms - Proposed range: from 0 s up to 10 s
Duration Class Strong From Con_t_Min_FC_P_or_FC_P_A Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep. - Proposed resolution: steps of 0,5 s - Proposed range: from 0 s up to 3600 s