Created: | 30.11.2022 10:55:03 |
Modified: | 18.01.2023 13:58:10 |
![]() |
|
![]() |
Attribute | ||
Private boolean acceptsDrfc_Il |
||
![]()
|
||
Private boolean acceptsDrfc_m |
||
![]()
|
||
Private boolean acceptsUfl |
||
![]()
|
||
Private boolean variantA_B |
||
![]()
|
Element | Source Role | Target Role |
Duration Class |
Name: hasInhibitionTimer |
Name: |
![]() Con_t_Inhibition_Timer<br/>The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable.<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 100 ms up to 10 s<br/>
|
||
Duration Class |
Name: hasMaxFcpOrFcpa |
Name: |
![]() Con_t_Max_FC_P_or_FC_P_A<br/>The maximum delay between detecting a sweeping train and confirmation of a successful sweeping.<br/>- Proposed resolution: steps of 1 s<br/>- Proposed range: from 0 s up to 7200 s<br/><br/>
|
||
Duration Class |
Name: hasDelayOfNotificationOfAvailability |
Name: |
![]() Con_t_Delay_Of_Notification_Of_Availability<br/>Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem -<br/>Electronic Interlocking, following the state change of a TVPS from occupied to vacant<br/>- Proposed resolution: steps of 100 ms<br/>- Proposed range: from 0 s up to 10 s<br/><br/>
|
||
Duration Class |
Name: hasMinFcpOrFcpa |
Name: |
![]() Con_t_Min_FC_P_or_FC_P_A<br/>Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep.<br/>- Proposed resolution: steps of 0,5 s<br/>- Proposed range: from 0 s up to 3600 s<br/><br/>
|
Property | Value |
isFinalSpecialization: | 0 |
Object | Type | Connection | Direction | Notes |
Eu.TDS.1215 | Requirement | Realization | To | |
Eu.TDS.7037 | Requirement | Realization | To | |
Eu.TDS.7037 | Requirement | Realization | To | |
Duration | Class | Strong | From | Con_t_Inhibition_Timer The duration between the detection of a passing for a TVPS (incoming, outgoing wheel or uninterpretable pattern) and the moment that the state of a TVPS is considered stable. - Proposed resolution: steps of 100 ms - Proposed range: from 100 ms up to 10 s |
Eu.TDS.1212 | Requirement | Realization | To | |
TdsSectionConfiguration | Class | Generalization | To | |
Eu.TDS.7039 | Requirement | Realization | To | |
Eu.TDS.1214 | Requirement | Realization | To | |
Eu.TDS.1213 | Requirement | Realization | To | |
Duration | Class | Strong | From | Con_t_Max_FC_P_or_FC_P_A The maximum delay between detecting a sweeping train and confirmation of a successful sweeping. - Proposed resolution: steps of 1 s - Proposed range: from 0 s up to 7200 s |
Duration | Class | Strong | From | Con_t_Delay_Of_Notification_Of_Availability Delay in milliseconds of reporting vacant from the Subsystem - Train Detection System to the Subsystem - Electronic Interlocking, following the state change of a TVPS from occupied to vacant - Proposed resolution: steps of 100 ms - Proposed range: from 0 s up to 10 s |
Duration | Class | Strong | From | Con_t_Min_FC_P_or_FC_P_A Timer that starts with the first detected incoming wheel, used for plausibility check. An outgoing wheel before expiry marks a failed sweep. - Proposed resolution: steps of 0,5 s - Proposed range: from 0 s up to 3600 s |
AxleCountingSectionConfiguration | Class | Generalization | From | |
Eu.TDS.4881 | Requirement | Realization | To |