Configuration of a Movable Element : Public abstract Class
A set of properties that applies to a movable element.<br/>
- Attributes
- Associations To
- Associations From
- Advanced
- Other Links
Attribute |
Private boolean canRedrive
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Notes:
|
True when this point controller is configured to redrive the movable element to its last reported position.<br/>
|
|
Private boolean hasFourWireInterface
|
Details:
Alias: |
|
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
|
Transient: |
False |
Derived: |
False |
IsID: |
False |
Notes:
|
True: this point controller has a 4-wire interface with the point machine. <br/>False: different number of wires.<br/>
|
|
Element |
Source Role |
Target Role |
MovableElement
Class
|
Name:
|
Name: appliesToMovableElement
|
 Details:
|
Element |
Source Role |
Target Role |
MovableElementOperatingModes
Enumeration
|
Name: isInOperatingMode
|
Name:
|
 Details:
|
ControlModes
Enumeration
|
Name: isInControlMode
|
Name:
|
 Details:
|
Duration
Class
|
Name: hasMaxOperationDuration
|
Name:
|
 Details:
Con_tmax_Point_Operation, the maximum time during which the object controller shall try to drive the movable element. <br/>This parameter is mostly given by generic rules but can be configurable.<br/>The timer starts with the command Moving to the Point machines and defines the max. time span after the Point has to arrive to an End position. After that time span the command Moving to the Point machines is set to Stop moving.<br/>resolution: steps of 100 ms.<br/>range: Between 100 ms and 30 s<br/><br/>
|
Property |
Value |
isFinalSpecialization: |