Configuration of a Movable Element : Public abstract Class
Created: 11.04.2019 09:21:14
Modified: 11.11.2021 12:30:35
Project:
Advanced:
A set of properties that applies to a movable element.<br/>
Attribute
Private boolean
  canRedrive
Details:
Notes: True when this point controller is configured to redrive the movable element to its last reported position.<br/>
Private boolean
  hasFourWireInterface
Details:
Notes: True:  this point controller has a 4-wire interface with the point machine. <br/>False: different number of wires.<br/>
Element Source Role Target Role
MovableElement
Class  
Name:  
 
Name: appliesToMovableElement
 
Details:
 
Element Source Role Target Role
MovableElementOperatingModes
Enumeration  
Name: isInOperatingMode
 
Name:  
 
Details:
 
ControlModes
Enumeration  
Name: isInControlMode
 
Name:  
 
Details:
 
Duration
Class  
Name: hasMaxOperationDuration
 
Name:  
 
Details:
Con_tmax_Point_Operation, the maximum time during which the object controller shall try to drive the movable element. <br/>This parameter is mostly given by generic rules but can be configurable.<br/>The timer starts with the command Moving to the Point machines and defines the max. time span after the Point has to arrive to an End position. After that time span the command Moving to the Point machines is set to Stop moving.<br/>resolution: steps of 100 ms.<br/>range: Between 100 ms and 30 s<br/><br/>
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
MovableElementOperatingModes Enumeration Strong From  
Eu.P.6636 Requirement Realization To  
DerailerElementConfiguration Class Generalization From  
PD-0532 - Lock type Requirement Realization To  
TrackAssetConfiguration Class Generalization To  
ControlModes Enumeration Strong From  
Eu.P.6293 Requirement Realization To  
Eu.P.2439 Requirement Realization To  
PointCrossingElementConfiguration Class Generalization From  
Duration Class Strong From Con_tmax_Point_Operation, the maximum time during which the object controller shall try to drive the movable element. This parameter is mostly given by generic rules but can be configurable. The timer starts with the command Moving to the Point machines and defines the max. time span after the Point has to arrive to an End position. After that time span the command Moving to the Point machines is set to Stop moving. resolution: steps of 100 ms. range: Between 100 ms and 30 s
PD-0521 - Point operating mode Requirement Realization To  
PD-0511 - Derailer operating mode Requirement Realization To  
PD-0508 - Point crossing derailer adjusting type Requirement Realization To  
PD-0534 - Lock type Requirement Realization To