TPS Relation : Public Class
Created: 17.10.2019 09:50:51
Modified: 16.11.2021 16:57:10
Project:
Advanced:
Informs at what distance the TP device or system is placed on approach to the signal. <br/>The signal could be a speed restriction board (NR approach).<br/>
Element Source Role Target Role
TpsDevice
Class  
Name:  
 
Name: appliesToTpsDevice
 
Details:
 
DataPrepEntities
Class  
Name: ownsTpsRelation
 
Name:  
 
Details:
 
TpsDataTransmissionSystem
Class  
Name:  
 
Name: appliesToTpsDataTxSystem
 
Details:
Applies to a TPS data transmission system.<br/>
Signal
Class  
Name:  
 
Name: appliesToRelatedSignal
 
Details:
The TPS device can reference repeater signals, stop marker boards, distant signals (DB).<br/>
BufferStop
Class  
Name:  
 
Name: appliesToBufferStop
 
Details:
States that the TP system protects a buffer stop (in use with ProRail and NR).<br/>
Signal
Class  
Name:  
 
Name: appliesToSignal
 
Details:
The signal that dictates the position of the TPS device. This is given with the distance from the signal.<br/>
Element Source Role Target Role
Length
Class  
Name: hasDistanceFromTpsToSignal
 
Name:  
 
Details:
Required distance from the TP device or system to the signal.<br/>
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
TP-0601 - SignalRef Requirement Realization To  
DataPrepEntities Class Strong To  
TP-1304 - Bufferstop reference Requirement Realization To  
TP-1403 - Signal reference Requirement Realization To  
SI-0425 - AWSMagnetRef Requirement Realization To  
TP-0807 - Speed checking system distance divergent Requirement Realization To  
TP-1002 - ID Signal Requirement Realization To  
TP-09 - Intermittent train protection element assignment Requirement Realization To  
TP-10 - Intermittent train protection signal assignment Requirement Realization To  
TP-0801 - ID Intermittent train protection element assignment Requirement Realization To  
SI-0424 - DistanceToAWSMagnet Requirement Realization To  
TP-1303 - Signal reference Requirement Realization To  
TP-0902 - ID Intermittent train protection element reference point Requirement Realization To  
TP-0335 - AssociatedSignal Requirement Realization To  
TP-0804 - Intermittent train protection distance to signal Requirement Realization To  
TP-1001 - ID Intermittent train protection element assignment Requirement Realization To  
SI-0423 - AWSMagnet Requirement Realization To  
ConfiguredBaseObject Class Generalization To  
KvbRelation Class Generalization From  
Length Class Strong From Required distance from the TP device or system to the signal.
Eu.LS.6090 Requirement Realization To