Created: | 13.10.2015 13:04:12 |
Modified: | 11.11.2021 17:22:38 |
![]() |
|
![]() |
Attribute | ||
Private boolean standoutControl |
||
![]()
|
Element | Source Role | Target Role |
Signal Class |
Name: |
Name: refersToRsmSignal |
![]() A EULYNX DP signal refers to the equivalent signal in the RSM namespace. Information about location in the railway network and position on the map is stored in the RSM namespace.<br/>
|
||
Overlap Class |
Name: |
Name: refersToOverlapsForDisplay |
![]() An ordered list of overlaps can express a preference for overlaps (displayed in the signaller's UI), from entry 1 down to entry n. E.g. if overlap 1 cannot be locked, try and lock overlap 2, etc. The implementation depends on national rules and regulations.<br/><br/>The list of overlaps is ordered so the signaller's display shows the overlaps in the given sequence.<br/>
|
||
SignalLocation Class |
Name: |
Name: hasLocation |
![]() |
||
SafetyDistance Class |
Name: |
Name: refersToSafetyDistance |
![]() An exit signal has a list of safety distances, i.e. overlap or danger point.<br/>
|
||
SignalFrame Class |
Name: |
Name: hasSignalFrame |
![]() A signal has one or more signal frames. A signal frame has an aspect that is either passive or active, i.e. that can change aspect. <br/>A non-physical signal has no frame<br/>
|
||
ActiveAspectSet Class |
Name: |
Name: showsDefaultActiveAspectSet |
![]() The default set of active aspects that the signal shows after startup and at rest (most restrictive message/aspect).<br/>
|
Element | Source Role | Target Role |
TpsRelation Class |
Name: |
Name: appliesToSignal |
![]() The signal that dictates the position of the TPS device. This is given with the distance from the signal.<br/>
|
||
ChangeMarker Class |
Name: |
Name: hasTracksideSignal |
![]() Signal(s) (real or virtual) marking the change.<br/>
|
||
EtcsSignalProperties Class |
Name: |
Name: appliesToSignal |
![]() Refers to signal, a light signal (for overlay signalling) or a marker board (pure ETCS signalling).<br/>
|
||
ArsSignalGroup Class |
Name: |
Name: refersToSignalInGroup |
![]() Refers to a signal that is included in the group.<br/>
|
||
EtcsConditionalEmergencyStopMarker Class |
Name: |
Name: appliesToSignal |
![]() Pointer to the signal or stop marker board where the CES is issued.<br/>
|
||
RouteConvergencyConflict Class |
Name: |
Name: appliesToSignal |
![]() |
||
TunnelSignalTimer Class |
Name: |
Name: closesSignal |
![]() The tunnel approach signal.<br/>
|
||
SignalAndMessage Class |
Name: |
Name: appliesToSignal |
![]() |
||
PopGroupAssociation Class |
Name: |
Name: appliesToSignal |
![]() |
||
AutomaticTypes Enumeration |
Name: isOfAutomaticType |
Name: |
![]() Signal is part of an autoworking route. <br/>
|
||
BaliseGroupPurpose Class |
Name: |
Name: refersToSignal |
![]() |
||
SignalProperty Class |
Name: hasProperty |
Name: |
![]() |
||
DispatchAnnouncerAssignment Class |
Name: |
Name: appliesToEntrySignal |
![]() The signal(s) at the entry of routes that the train is due to use.<br/>
|
||
TrainDescriberDisplayField Class |
Name: |
Name: refersToSignal |
![]() |
||
BackToBackLocking Class |
Name: |
Name: appliesToSignal |
![]() |
||
RouteExtremity Class |
Name: |
Name: isAssociatedWithSignal |
![]() |
||
ArsRouteTrigger Class |
Name: |
Name: refersToDistantSignal |
![]() Reference to a distant signal that governs the calculation of the ARS route trigger.<br/>
|
||
LeuCabinetLocation Class |
Name: |
Name: refersToSignal |
![]() Reference to the signal where the LEU cabinet is placed.<br/><br/>
|
||
FixingTypes Enumeration |
Name: isDesignedForFixingType |
Name: |
![]() General information about the fixing of a signal. Mainly used in early design phase and cost calculations.<br/>
|
||
NonStoppingPoint Class |
Name: |
Name: refersToEtcsSignal |
![]() The signal in advance of the non-stopping point.<br/>
|
||
DepartureTrack Class |
Name: |
Name: refersToSignal |
![]() The signal whence the train leaves the departure track.<br/>nl-NL: <u>Referentie</u> <u>naar</u> <u>het</u> (<u>vertrek</u>)<u>sein</u>. <u>Hiermee</u> <u>wordt</u> <u>de</u> <u>rijrichting</u> <u>bepaald</u>.<br/><br/>
|
||
SignalPostTelephone Class |
Name: |
Name: appliesToSignal |
![]() |
||
LeuSystem Class |
Name: |
Name: isRelatedToSignal |
![]() The signal, SMB or light signal associated and controlling the LEU. Typically used to generate the designation of the LEU.<br/>
|
||
TpMarker Class |
Name: |
Name: refersToBoundarySignal |
![]() Reference to a signal at the transition.<br/>The actual technical transition can have an offset with respect to the signal position (i.e. "early" or "late" transition)<br/>de-DE: Einstiegssignal. Bei Einstieg ohne bekanntes rückwertiges Signal ist hier kein Signal vorgegeben.<br/><br/>
|
||
TpsRelation Class |
Name: |
Name: appliesToRelatedSignal |
![]() The TPS device can reference repeater signals, stop marker boards, distant signals (DB).<br/>
|
||
NonStopMovement Class |
Name: |
Name: appliesToSignal |
![]() |
||
SpadAlarm Class |
Name: |
Name: appliesToSignal |
![]() SPAD detection is configured for this signal.<br/>
|
||
ZbsPartialRouteExtremity Class |
Name: |
Name: isAssociatedWithSignal |
![]() Partial route body is limited by signal.<br/>de-DE: Fahrwegteil wird begrenzt durch einen Signal.<br/>
|
||
IlluminationTypes Enumeration |
Name: isOfIlluminationType |
Name: |
![]() The type of external lighting.<br/>
|
||
TpsProtectionDistance Class |
Name: |
Name: appliesToSignal |
![]() |
||
FlankProtection Class |
Name: |
Name: isProvidedBySignal |
![]() |
||
TriggerAssignment Class |
Name: |
Name: clearsSignal |
![]() The detection of a vehicle passage can clear a signal.<br/>For instance: in shunting areas, a treadle can clear the shunting signal.<br/>
|
||
ManualOverlapRelease Class |
Name: |
Name: appliesToSignal |
![]() |
||
EtcsLevelTransitionMarker Class |
Name: |
Name: hasAccessControlSignal |
![]() Signal(s) that prevent unsuitable trains from transiting.<br/>de-DE: ausschließlich für ETCS L2 oS (ohne Signale)<br/>
|
||
TrainDescriberSteppingCriterion Class |
Name: |
Name: steppingStartSignal |
![]() Reference to the main signal that governs the stepping criterion.<br/>
|
||
Segment Class |
Name: |
Name: hasTracksideSignal |
![]() A segment refers to signals that indicate the new property like speed at or near the beginning of that segment. Note that a signal has its own spot location.<br/>fr-FR: permet d'associer un signal limite de vitesse en aval. Ne sera pas utilisé en France.<br/>
|
||
OppositeTrackSignal Class |
Name: |
Name: appliesToSignal |
![]() |
||
RouteApproachLocking Class |
Name: |
Name: locksEntrySignal |
![]() Locks the proceed aspect of an entry signal.<br/>
|
||
TriggerAssignment Class |
Name: |
Name: closesSignal |
![]() Condition that forces the signal to close.<br/>This extra condition typically complements another condition that may close the signal earlier. <br/>The extra condition can be signal passed at danger (SPAD). In this case, more than one signal in the vicinity can be closed as a protective measure.<br/>de-DE: zweites Haltfallkriterium<br/>fr-FR: AXF Auxiliaire de Fermeture<br/>
|
||
RouteEntry Class |
Name: |
Name: hasGroupMainSignal |
![]() Pointer to group signal.<br/>
|
Tag | Value |
mixed | false |
![]() Values: true | false
Default: false Description: Determines whether this element may contain mixed element and character content. |
|
modelGroup | sequence |
![]() Values: all | sequence | choice
Default: sequence Description: Overrides the package-level default model group |
Property | Value |
isFinalSpecialization: | 0 |
Object | Type | Connection | Direction | Notes |
SI-0384 - Lateral distance | Requirement | Realization | To | |
FP-0207 - ID Flank protection signal | Requirement | Realization | To | |
AR-0602 - ID Signal | Requirement | Realization | To | |
SI-03 - Signal | Requirement | Realization | To | |
TP-1002 - ID Signal | Requirement | Realization | To | |
SI-0115 - TrackRef | Requirement | Realization | To | |
RO-0508 - Overlap sequence | Requirement | Realization | To | |
TrackAsset | Class | Generalization | To | |
SI-0305 - Route special | Requirement | Realization | To | |
SI-0379 - Location object TOP edge | Requirement | Realization | To | |
SI-0114 - EffectivePoint | Requirement | Realization | To | |
SI-0117 - Direction | Requirement | Realization | To | |
SI-0385 - Location description | Requirement | Realization | To | |
TP-1001 - ID Intermittent train protection element assignment | Requirement | Realization | To | |
TP-0902 - ID Intermittent train protection element reference point | Requirement | Realization | To | |
SI-0116 - Chainage | Requirement | Realization | To | |
SI-0437 - ID Second criteria for signal closing | Requirement | Realization | To | |
SI-0378 - Line kilometer | Requirement | Realization | To | |
SI-0364 - Automatic setting | Requirement | Realization | To | |
SI-0383 - Lateral position | Requirement | Realization | To | |
SI-0438 - Occupied exit from stub track | Requirement | Realization | To | |
AutomaticTypes | Enumeration | Strong | From | Signal is part of an autoworking route. |
TP-1403 - Signal reference | Requirement | Realization | To | |
SignalProperty | Class | Strong | From | |
SI-0405 - Signal post telephone reference | Requirement | Realization | To | |
SI-0377 - ID Line | Requirement | Realization | To | |
SI-0376 - Location object line | Requirement | Realization | To | |
SI-0505 - Illuminated | Requirement | Realization | To | |
RO-1603 - ID Signal | Requirement | Realization | To | |
NonPhysicalSignal | Class | Generalization | From | |
AR-0702 - ID Distant signal | Requirement | Realization | To | |
SignalType | Class | Dependency | From | |
FixingTypes | Enumeration | Strong | From | General information about the fixing of a signal. Mainly used in early design phase and cost calculations. |
SI-0802 - ID Entry signal announced | Requirement | Realization | To | |
TP-0335 - AssociatedSignal | Requirement | Realization | To | |
Eu.LS.6090 | Requirement | Realization | To | |
TP-0601 - SignalRef | Requirement | Realization | To | |
SI-0439 - Validity area | Requirement | Realization | To | |
TS-1013 - ID Stepping start | Requirement | Realization | To | |
SignalFunction | Class | Dependency | From | |
SI-0381 - Distance | Requirement | Realization | To | |
SI-0360 - Radio coverage GSMR | Requirement | Realization | To | |
IlluminationTypes | Enumeration | Strong | From | The type of external lighting. |
LightSignal | Class | Dependency | From | |
PhysicalSignal | Class | Generalization | From | |
SI-0704 - ID Signal | Requirement | Realization | To | |
SI-0306 - Opposite track | Requirement | Realization | To | |
SI-0382 - Effective direction | Requirement | Realization | To | |
RBC | Class | Abstraction | To | All signals, including marker boards are within the control area of an RBC (see diagram Area). Active signals, which includes light signals, are controlled track assets so they have a control relation with the RBC (see diagram Control and power relation). |
SI-0366 - Signal fixing type | Requirement | Realization | To | |
SI-0101 - EquipmentSupportRef | Requirement | Realization | To | |
TP-1303 - Signal reference | Requirement | Realization | To | |
TD-0501 - ID Request | Requirement | Realization | To | |
FP-0205 - Flank protection signal | Requirement | Realization | To | |
SI-0425 - AWSMagnetRef | Requirement | Realization | To |