| Created: | 13.10.2015 13:04:12 |
| Modified: | 11.11.2021 17:22:38 |
Project: |
|
Advanced: |
|
| Attribute | ||
|
Private boolean standoutControl |
||
Details:
|
| Element | Source Role | Target Role |
|
Signal Class |
Name: |
Name: refersToRsmSignal |
Details:
A EULYNX DP signal refers to the equivalent signal in the RSM namespace. Information about location in the railway network and position on the map is stored in the RSM namespace.<br/>
|
||
|
Overlap Class |
Name: |
Name: refersToOverlapsForDisplay |
Details:
An ordered list of overlaps can express a preference for overlaps (displayed in the signaller's UI), from entry 1 down to entry n. E.g. if overlap 1 cannot be locked, try and lock overlap 2, etc. The implementation depends on national rules and regulations.<br/><br/>The list of overlaps is ordered so the signaller's display shows the overlaps in the given sequence.<br/>
|
||
|
SignalLocation Class |
Name: |
Name: hasLocation |
Details:
|
||
|
SafetyDistance Class |
Name: |
Name: refersToSafetyDistance |
Details:
An exit signal has a list of safety distances, i.e. overlap or danger point.<br/>
|
||
|
SignalFrame Class |
Name: |
Name: hasSignalFrame |
Details:
A signal has one or more signal frames. A signal frame has an aspect that is either passive or active, i.e. that can change aspect. <br/>A non-physical signal has no frame<br/>
|
||
|
ActiveAspectSet Class |
Name: |
Name: showsDefaultActiveAspectSet |
Details:
The default set of active aspects that the signal shows after startup and at rest (most restrictive message/aspect).<br/>
|
||
| Element | Source Role | Target Role |
|
TpsRelation Class |
Name: |
Name: appliesToSignal |
Details:
The signal that dictates the position of the TPS device. This is given with the distance from the signal.<br/>
|
||
|
ChangeMarker Class |
Name: |
Name: hasTracksideSignal |
Details:
Signal(s) (real or virtual) marking the change.<br/>
|
||
|
EtcsSignalProperties Class |
Name: |
Name: appliesToSignal |
Details:
Refers to signal, a light signal (for overlay signalling) or a marker board (pure ETCS signalling).<br/>
|
||
|
ArsSignalGroup Class |
Name: |
Name: refersToSignalInGroup |
Details:
Refers to a signal that is included in the group.<br/>
|
||
|
EtcsConditionalEmergencyStopMarker Class |
Name: |
Name: appliesToSignal |
Details:
Pointer to the signal or stop marker board where the CES is issued.<br/>
|
||
|
RouteConvergencyConflict Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
TunnelSignalTimer Class |
Name: |
Name: closesSignal |
Details:
The tunnel approach signal.<br/>
|
||
|
SignalAndMessage Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
PopGroupAssociation Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
AutomaticTypes Enumeration |
Name: isOfAutomaticType |
Name: |
Details:
Signal is part of an autoworking route. <br/>
|
||
|
BaliseGroupPurpose Class |
Name: |
Name: refersToSignal |
Details:
|
||
|
SignalProperty Class |
Name: hasProperty |
Name: |
Details:
|
||
|
DispatchAnnouncerAssignment Class |
Name: |
Name: appliesToEntrySignal |
Details:
The signal(s) at the entry of routes that the train is due to use.<br/>
|
||
|
TrainDescriberDisplayField Class |
Name: |
Name: refersToSignal |
Details:
|
||
|
BackToBackLocking Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
RouteExtremity Class |
Name: |
Name: isAssociatedWithSignal |
Details:
|
||
|
ArsRouteTrigger Class |
Name: |
Name: refersToDistantSignal |
Details:
Reference to a distant signal that governs the calculation of the ARS route trigger.<br/>
|
||
|
LeuCabinetLocation Class |
Name: |
Name: refersToSignal |
Details:
Reference to the signal where the LEU cabinet is placed.<br/><br/>
|
||
|
FixingTypes Enumeration |
Name: isDesignedForFixingType |
Name: |
Details:
General information about the fixing of a signal. Mainly used in early design phase and cost calculations.<br/>
|
||
|
NonStoppingPoint Class |
Name: |
Name: refersToEtcsSignal |
Details:
The signal in advance of the non-stopping point.<br/>
|
||
|
DepartureTrack Class |
Name: |
Name: refersToSignal |
Details:
The signal whence the train leaves the departure track.<br/>nl-NL: <u>Referentie</u> <u>naar</u> <u>het</u> (<u>vertrek</u>)<u>sein</u>. <u>Hiermee</u> <u>wordt</u> <u>de</u> <u>rijrichting</u> <u>bepaald</u>.<br/><br/>
|
||
|
SignalPostTelephone Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
LeuSystem Class |
Name: |
Name: isRelatedToSignal |
Details:
The signal, SMB or light signal associated and controlling the LEU. Typically used to generate the designation of the LEU.<br/>
|
||
|
TpMarker Class |
Name: |
Name: refersToBoundarySignal |
Details:
Reference to a signal at the transition.<br/>The actual technical transition can have an offset with respect to the signal position (i.e. "early" or "late" transition)<br/>de-DE: Einstiegssignal. Bei Einstieg ohne bekanntes rückwertiges Signal ist hier kein Signal vorgegeben.<br/><br/>
|
||
|
TpsRelation Class |
Name: |
Name: appliesToRelatedSignal |
Details:
The TPS device can reference repeater signals, stop marker boards, distant signals (DB).<br/>
|
||
|
NonStopMovement Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
SpadAlarm Class |
Name: |
Name: appliesToSignal |
Details:
SPAD detection is configured for this signal.<br/>
|
||
|
ZbsPartialRouteExtremity Class |
Name: |
Name: isAssociatedWithSignal |
Details:
Partial route body is limited by signal.<br/>de-DE: Fahrwegteil wird begrenzt durch einen Signal.<br/>
|
||
|
IlluminationTypes Enumeration |
Name: isOfIlluminationType |
Name: |
Details:
The type of external lighting.<br/>
|
||
|
TpsProtectionDistance Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
FlankProtection Class |
Name: |
Name: isProvidedBySignal |
Details:
|
||
|
TriggerAssignment Class |
Name: |
Name: clearsSignal |
Details:
The detection of a vehicle passage can clear a signal.<br/>For instance: in shunting areas, a treadle can clear the shunting signal.<br/>
|
||
|
ManualOverlapRelease Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
EtcsLevelTransitionMarker Class |
Name: |
Name: hasAccessControlSignal |
Details:
Signal(s) that prevent unsuitable trains from transiting.<br/>de-DE: ausschließlich für ETCS L2 oS (ohne Signale)<br/>
|
||
|
TrainDescriberSteppingCriterion Class |
Name: |
Name: steppingStartSignal |
Details:
Reference to the main signal that governs the stepping criterion.<br/>
|
||
|
Segment Class |
Name: |
Name: hasTracksideSignal |
Details:
A segment refers to signals that indicate the new property like speed at or near the beginning of that segment. Note that a signal has its own spot location.<br/>fr-FR: permet d'associer un signal limite de vitesse en aval. Ne sera pas utilisé en France.<br/>
|
||
|
OppositeTrackSignal Class |
Name: |
Name: appliesToSignal |
Details:
|
||
|
RouteApproachLocking Class |
Name: |
Name: locksEntrySignal |
Details:
Locks the proceed aspect of an entry signal.<br/>
|
||
|
TriggerAssignment Class |
Name: |
Name: closesSignal |
Details:
Condition that forces the signal to close.<br/>This extra condition typically complements another condition that may close the signal earlier. <br/>The extra condition can be signal passed at danger (SPAD). In this case, more than one signal in the vicinity can be closed as a protective measure.<br/>de-DE: zweites Haltfallkriterium<br/>fr-FR: AXF Auxiliaire de Fermeture<br/>
|
||
|
RouteEntry Class |
Name: |
Name: hasGroupMainSignal |
Details:
Pointer to group signal.<br/>
|
||
| Tag | Value |
| mixed | false |
Details:
Values: true | false
Default: false Description: Determines whether this element may contain mixed element and character content. |
|
| modelGroup | sequence |
Details:
Values: all | sequence | choice
Default: sequence Description: Overrides the package-level default model group |
|
| Property | Value |
| isFinalSpecialization: | 0 |
| Object | Type | Connection | Direction | Notes |
| SI-0384 - Lateral distance | Requirement | Realization | To | |
| FP-0207 - ID Flank protection signal | Requirement | Realization | To | |
| AR-0602 - ID Signal | Requirement | Realization | To | |
| SI-03 - Signal | Requirement | Realization | To | |
| TP-1002 - ID Signal | Requirement | Realization | To | |
| SI-0115 - TrackRef | Requirement | Realization | To | |
| RO-0508 - Overlap sequence | Requirement | Realization | To | |
| TrackAsset | Class | Generalization | To | |
| SI-0305 - Route special | Requirement | Realization | To | |
| SI-0379 - Location object TOP edge | Requirement | Realization | To | |
| SI-0114 - EffectivePoint | Requirement | Realization | To | |
| SI-0117 - Direction | Requirement | Realization | To | |
| SI-0385 - Location description | Requirement | Realization | To | |
| TP-1001 - ID Intermittent train protection element assignment | Requirement | Realization | To | |
| TP-0902 - ID Intermittent train protection element reference point | Requirement | Realization | To | |
| SI-0116 - Chainage | Requirement | Realization | To | |
| SI-0437 - ID Second criteria for signal closing | Requirement | Realization | To | |
| SI-0378 - Line kilometer | Requirement | Realization | To | |
| SI-0364 - Automatic setting | Requirement | Realization | To | |
| SI-0383 - Lateral position | Requirement | Realization | To | |
| SI-0438 - Occupied exit from stub track | Requirement | Realization | To | |
| AutomaticTypes | Enumeration | Strong | From | Signal is part of an autoworking route. |
| TP-1403 - Signal reference | Requirement | Realization | To | |
| SignalProperty | Class | Strong | From | |
| SI-0405 - Signal post telephone reference | Requirement | Realization | To | |
| SI-0377 - ID Line | Requirement | Realization | To | |
| SI-0376 - Location object line | Requirement | Realization | To | |
| SI-0505 - Illuminated | Requirement | Realization | To | |
| RO-1603 - ID Signal | Requirement | Realization | To | |
| NonPhysicalSignal | Class | Generalization | From | |
| AR-0702 - ID Distant signal | Requirement | Realization | To | |
| SignalType | Class | Dependency | From | |
| FixingTypes | Enumeration | Strong | From | General information about the fixing of a signal. Mainly used in early design phase and cost calculations. |
| SI-0802 - ID Entry signal announced | Requirement | Realization | To | |
| TP-0335 - AssociatedSignal | Requirement | Realization | To | |
| Eu.LS.6090 | Requirement | Realization | To | |
| TP-0601 - SignalRef | Requirement | Realization | To | |
| SI-0439 - Validity area | Requirement | Realization | To | |
| TS-1013 - ID Stepping start | Requirement | Realization | To | |
| SignalFunction | Class | Dependency | From | |
| SI-0381 - Distance | Requirement | Realization | To | |
| SI-0360 - Radio coverage GSMR | Requirement | Realization | To | |
| IlluminationTypes | Enumeration | Strong | From | The type of external lighting. |
| LightSignal | Class | Dependency | From | |
| PhysicalSignal | Class | Generalization | From | |
| SI-0704 - ID Signal | Requirement | Realization | To | |
| SI-0306 - Opposite track | Requirement | Realization | To | |
| SI-0382 - Effective direction | Requirement | Realization | To | |
| RBC | Class | Abstraction | To | All signals, including marker boards are within the control area of an RBC (see diagram Area). Active signals, which includes light signals, are controlled track assets so they have a control relation with the RBC (see diagram Control and power relation). |
| SI-0366 - Signal fixing type | Requirement | Realization | To | |
| SI-0101 - EquipmentSupportRef | Requirement | Realization | To | |
| TP-1303 - Signal reference | Requirement | Realization | To | |
| TD-0501 - ID Request | Requirement | Realization | To | |
| FP-0205 - Flank protection signal | Requirement | Realization | To | |
| SI-0425 - AWSMagnetRef | Requirement | Realization | To |