: Public Class
Created: 06.05.2020 17:47:15
Modified: 14.12.2021 16:46:37
Project:
Advanced:
Quantity of type length, distance, height, width, etc.<br/>
Element Source Role Target Role
PresignProperties
Class  
Name: hasDistanceSKprime
 
Name:  
 
Details:
de-DE: Räumstrecke dSK' gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).<br/>
CircularTurnout
Class  
Name: radius
 
Name:  
 
Details:
 
VerticalSegmentTransition
Class  
Name: initialRadius
 
Name:  
 
Details:
The radius of the circle tangential to the beginning of the segment.<br/>Start and end with respect to the orientation of the linear element of the topology that carries the segment.<br/>
SignalSightingDistance
Class  
Name: hasMinimumDistance
 
Name:  
 
Details:
Minimal distance calculated based on the minimum response time, the signal complexity and the local speed. <br/>Fixed in national rules, sometimes adapted to local circumstances.<br/>
LinearCoordinate
Class  
Name: lateralOffset
 
Name:  
 
Details:
Lateral offset. The sign is always positive and the side, left or right, is given by the spot location's lateral side.<br/>
FtgsTrackCircuitProperties
Class  
Name: hasLengthE
 
Name:  
 
Details:
Electric length of FTGS subsection E1, E2, E3 (See the FTG S documentation).<br/>
PresignProperties
Class  
Name: hasDistanceCK
 
Name:  
 
Details:
de-DE: Räumstrecke dCK gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).<br/>
LinearCoordinate
Class  
Name: measure
 
Name:  
 
Details:
Distance from the anchor point.<br/>
AnchorPoint
Class  
Name: restartValue
 
Name:  
 
Details:
The measure value of the anchor point, e.g. km 47.5<br/>ISO19148:2021 uses the term "RestartValue".<br/>
TpsRelation
Class  
Name: hasDistanceFromTpsToSignal
 
Name:  
 
Details:
Required distance from the TP device or system to the signal.<br/>
VerticalAlignmentSegment
Class  
Name: length
 
Name:  
 
Details:
The length of the segment when projected on the vertical surface. The length is optional because it may be irrelevant or may be derived from position information associated with the linear location.<br/>
SignalAlignmentPointOnTrack
Class  
Name: height
 
Name:  
 
Details:
height over the track of the alignment target <br/><br/>
SignalAlignmentPointOnTrack
Class  
Name: distance
 
Name:  
 
Details:
distance along the track to the alignment target <br/>
TpwsTrainCategorySpecificProperties
Class  
Name: hasMaximumOverrunDistance
 
Name:  
 
Details:
 
ZbsReducedSpeedProperties
Class  
Name: distanceToStartOfReducedSpeed
 
Name:  
 
Details:
Distance between BG and start of reduced speed section.<br/>de-DE: Distanz zwischen Datenpunkt und Beginn der Geschwindigkeitseinschränkung.<br/>
HorizontalSegmentArc
Class  
Name: radius
 
Name:  
 
Details:
Radius of the arc.<br/>
PresignProperties
Class  
Name: hasDistanceBK
 
Name:  
 
Details:
de-DE: Räumstrecke dBK gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).<br/>
SignalSightingDistance
Class  
Name: hasAchievableDistance
 
Name:  
 
Details:
Reading distance with the help of mitigation works, e.g. removing obstruction by foliage.<br/>
LevelCrossingSignalRelation
Class  
Name: hasDistanceToCrossing
 
Name:  
 
Details:
The distance between signal/sign and track crossing centre.<br/><br/>
SignalSightingDistance
Class  
Name: hasMinimumViewingDistance
 
Name:  
 
Details:
Smallest distance where the signal can be read. Closer to the signal, the driver may not be able to view the signal.<br/>
TpsProtectionDistance
Class  
Name: value
 
Name:  
 
Details:
The value of the TPS protection distance.<br/>
ChangeMarker
Class  
Name: appliesOverDistance
 
Name:  
 
Details:
The distance over which the change applies.<br/>
SignalSightingDistance
Class  
Name: hasAvailableDistance
 
Name:  
 
Details:
Reading distance without any mitigation works, i.e. assessed on site before removing obstructions.<br/>Applies either to a signal or to individual signal frame.<br/>
OffsetOfReferencePoint
Class  
Name: value
 
Name:  
 
Details:
The offset of the reference point with respect to:<br/><ul>
<li>the nearest rail (SNCF, NR).</li><li>the centre line of the track (DB).</li></ul><p/>
KvbTpsToTargetRelation
Class  
Name: hasDistanceFromSignalToTarget
 
Name:  
 
Details:
Distance between signal and target.<br/>fr-FR: distance entre signal et point but. Utilisée pour balise prox à distance de glissement entre 100m et 200m.<br/>
EtcsRouteApproachLocking
Class  
Name: hasLongRangeApproachDistance
 
Name:  
 
Details:
The distance for long range timeless revocation of the approach route. A train that is closer than this distance must cooperate in revoking the MA. <br/>
LxDepartureDetection
Class  
Name: hasSpeedRestrictionLength
 
Name:  
 
Details:
The distance over which the restricted speed applies. This allows the LX sufficient time to close.<br/>
AnchorPoint
Class  
Name: measureFromPrevious
 
Name:  
 
Details:
 
LowFrequencyTrackCircuitProperties
Class  
Name: hasInfluencedLength
 
Name:  
 
Details:
Influenced length for track circuit using the NF technology.<br/>
RoadTrafficLightProperties
Class  
Name: hasDistanceDf
 
Name:  
 
Details:
de-DE: Sperrstrecke als Abstand Lz/Andreaskreuz - gegenüberliegende Schranke (dF). Die Angabe ist nur bei beschrankten Bahnübergängen erforderlich.<br/>
TpsDataTransmissionSystemProperties
Class  
Name: hasExtensionLength
 
Name:  
 
Details:
The (positive) length over which a TP System <i>extends</i>. For instance: length of a balise group from first to last in group.<br/>
Canvas
Class  
Name: width
 
Name:  
 
Details:
Width of the canvas in a given unit (e.g. mm or pixel) if not implied in the canvas name.<br/>
Cant
Class  
Name: superelevation
 
Name:  
 
Details:
The height difference between the outer and inner rails in or in approach to a curve.<br/>The value is normally positive. It is negative in the exceptional case when the inner rail is higher.<br/>Corresponds to IFC4.3 IfcAlignmentCant attribute RailHeadDistance.<br/>
LineBlockInformation
Class  
Name: isDesignedForBrakingDistance
 
Name:  
 
Details:
The block line is designed for the given braking distance.<br/>Only used by DB for validation purposes.<br/>de-DE: Bremsweg als Grundlage für die Dimensionierung der zugehörigen Strecke.<br/>SNCF documents show the signals and the distances between signals, ergo no need for braking distance parameter. <br/>
LocalReference
Class  
Name: hasDistanceToLocation
 
Name:  
 
Details:
Distance from the referenced location (positive number).<br/>en-UK: set out distance<br/>
EtcsSignalProperties
Class  
Name: shortestOverlap50
 
Name:  
 
Details:
The shortest overlap in the category less than 50 metres.<br/>Only given when the interlocking can't dynamically provide the overlap length to the RBC.<br/>
BaliseGroupPurpose
Class  
Name: hasDistance
 
Name:  
 
Details:
The distance to the track asset that justifies the presence of the balise group.<br/>
RoadTrafficLightProperties
Class  
Name: hasDistanceD
 
Name:  
 
Details:
de-DE: Sperrstrecke als Abstand Lz/Andreaskreuz - gegenüberliegende Gefahrraumgrenze (d). Die Angabe ist nur bei unbeschrankten Bahnübergängen erforderlich.<br/>
RoadTrafficLightProperties
Class  
Name: hasDistanceD1
 
Name:  
 
Details:
de-DE: Angaben zur Sperrstrecke bei BÜ der Art LzH bzw. LzHH.<br/>Teilsperrstrecke als Abstand Lz - Schranke (d1). <br/>
SignalSightingDistance
Class  
Name: hasCombinedReadableDistance
 
Name:  
 
Details:
Combined reading distance for the signal and any associated repeaters.<br/>
PredefinedZbsTelegramSet
Class  
Name: needsSafetyDistance
 
Name:  
 
Details:
Safety distance that is needed beyond the target signal, given the release speed.<br/>de-DE: Erforderliche Schutzstrecke; hinter dem Zielsignal des Überwachungsabschnitts für die gewählte Freigabegeschwindigkeit geforderte Soll-Länge der Schutzstrecke.<br/>
EtcsConditionalEmergencyStopMarker
Class  
Name: hasOffset
 
Name:  
 
Details:
The CES can be shifted by a (positive) offset, always in rear of the signal. <br/>
BarrierBoom
Class  
Name: widthOfBlockedWay
 
Name:  
 
Details:
The span of roadway and pathway that is blocked by the lowered boom.<br/>de-DE: Sperrlaenge<br/>
PredefinedEtcsTelegramSetTilting
Class  
Name: hasZLA
 
Name:  
 
Details:
Target distance up to the start of the section of reduced speed.<br/>de-DE: Zielentfernung bis zum Beginn des La-Bereichs.<br/>
SignalSightingDistance
Class  
Name: hasPreferredDistance
 
Name:  
 
Details:
Distance at which the signal shall be visible if economically viable. Fixed in national rules. Always greater than the minimum distance.<br/><ul>
<li>For NR this maps to "required distance" and can also apply to the route indicators or shunting aspects.</li></ul>
<ul>
<li>de-DE: Sollsignalsicht.</li></ul><p/>
KvbTpsToTargetRelation
Class  
Name: hasDistanceFromTargetToFoulingPoint
 
Name:  
 
Details:
Distance from target to fouling point.<br/>fr-FR: distance entre point but et garage franc. Utilisée pour balise prox à distance de glissement entre 50m et 100m.<br/>
PathCrossingProperties
Class  
Name: hasWidth
 
Name:  
 
Details:
Width of an additional cycle or foot path that is adjacent to the main carriage way.<br/>
TpMarker
Class  
Name: hasChangeExecutionLength
 
Name:  
 
Details:
The change must have been completed with this distance (counting from the marker). <br/>Also known as transition length.<br/>This length would normally be calculated by design rules, derived from time/max speed, and can be recorded here for validation purposes.<br/><br/>
PlatformEdge
Class  
Name: hasHeight
 
Name:  
 
Details:
Height over nearest rail.<br/>Can be specialised in national domain if a national list of allowed heights applies.<br/>
CentralControlledAreaDepartureTrack
Class  
Name: hasUsableLength
 
Name:  
 
Details:
Length of track that departing trains can use.<br/>
VerticalSegmentArc
Class  
Name: radius
 
Name:  
 
Details:
Radius of the arc.<br/>
EtcsEndOfAuthority
Class  
Name: hasDistanceInRearOfSignal
 
Name:  
 
Details:
The ETCS EoA is located at a given distance in rear of the signal.<br/>
TrackCrossingProperties
Class  
Name: hasRoadWayWidth
 
Name:  
 
Details:
Width of the road/way that crosses the railway track. The width measure is governed by national rules. <br/>NR includes any cycle or foot path in the measure.<br/>
LinearPositioningSystem
Class  
Name: startMeasure
 
Name:  
 
Details:
The lowest value of the abscissa in the positioning system.<br/>
SandHump
Class  
Name: hasLength
 
Name:  
 
Details:
 
EtcsRouteApproachLocking
Class  
Name: usesStaffResponsibleDistance
 
Name:  
 
Details:
The distance in approach to the signal where no route cancellation for trains in SR is possible. <br/>
SpecialTrackGauge
Class  
Name: hasValue
 
Name:  
 
Details:
Dual gauge has two values for the distance between the rails, e.g. in CH.<br/>
PredefinedZbsTelegramSet
Class  
Name: hasSafetyDistance
 
Name:  
 
Details:
The safety distance that is actually available beyond the target signal of the supervised section.<br/>de-DE: Vorhandene Schutzstrecke; hinter dem Zielsignal des Überwachungsabschnitts vorhandene Ist-Länge der Schutzstrecke.<br/>
RoadTrafficLightProperties
Class  
Name: hasDistanceD2
 
Name:  
 
Details:
de-DE: Angaben zur Sperrstrecke bei BÜ der Art LzH bzw. LzHH.<br/>Räumstrecke als Abstand Schranke - gegenüberliegende Gefahrraumgrenze (d2). <br/>
PredefinedEtcsTelegramSetTilting
Class  
Name: hasLLA
 
Name:  
 
Details:
length of reduced speed section<br/>de-DE: Länge des La-Bereichs.<br/>
BarrierMechanism
Class  
Name: hasDistanceToPathEdge
 
Name:  
 
Details:
Distance between the barrier mechanism and the nearest edge of footway or carriageway that the barrier boom protects.<br/>Only stored if relevant.<br/>
EpsSignalProperties
Class  
Name: protectsTunnelOfLength
 
Name:  
 
Details:
Given only when this signal protects a tunnel entry. The tunnel then has the given length.<br/>
SpeedCheckingSystemProperties
Class  
Name: hasSpeedCheckingSectionLength
 
Name:  
 
Details:
Distance between two speed checking devices, also known as trip distance. <br/>NR: speed checking length maps to OSS spacing<br/>
LinearCoordinate
Class  
Name: verticalOffset
 
Name:  
 
Details:
Vertical offset. Can be positive or negative.<br/>
HorizontalSegmentTransition
Class  
Name: finalRadius
 
Name:  
 
Details:
Radius at the end of the segment.<br/>
PresignProperties
Class  
Name: hasDistanceAB
 
Name:  
 
Details:
de-DE: Räumstrecke dAB gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).<br/>
BaliseGroupLinking
Class  
Name: hasDistance
 
Name:  
 
Details:
Distance between from-to balise groups (N_PIG=0)<br/>
PredefinedZbsTelegramSet
Class  
Name: hasSectionOfLength
 
Name:  
 
Details:
Length of the supervised section.<br/>de-DE: Länge des Überwachungsabschnitts.<br/>
EtcsSignalProperties
Class  
Name: shortestOverlap50_200
 
Name:  
 
Details:
The shortest overlap in the category 50 to less than 200m.<br/>Only given when the interlocking can't dynamically provide the overlap length to the RBC.<br/>
EtcsSignalProperties
Class  
Name: shortestOverlap200
 
Name:  
 
Details:
Shortest overlap in the category 200m and upwards.<br/>Only given when the interlocking can't dynamically provide the overlap length to the RBC.<br/>
EtcsLevelTransitionMarker
Class  
Name: maxTrainLength
 
Name:  
 
Details:
Maximum train length for which the level transition is designed.<br/>de-DE: Max. Zuglänge für die Berechnung der Ausdehnung von Bereich "C".<br/>
TrackCircuitProperties
Class  
Name: hasElectricLength
 
Name:  
 
Details:
Electric length of the section, computed according to the regulations and the local particularities.<br/>
FtgsTrackCircuitProperties
Class  
Name: hasLengthS
 
Name:  
 
Details:
Electric length of FTGS subsection S (See the FTG S documentation).<br/>
ZbsReducedSpeedProperties
Class  
Name: lengthOfReducedSpeedSection
 
Name:  
 
Details:
Length of the reduced speed section.<br/>de-DE: Länge des Bereichs der Geschwindigkeitseinschränkung.<br/>
RadarReflector
Class  
Name: isMountedAtHeight
 
Name:  
 
Details:
The height over the ground level at which the reflector is mounted.<br/>
RouteApproachLocking
Class  
Name: hasDesignDistance
 
Name:  
 
Details:
The distance in approach to the signal that is required for the approach locking. Typically the designer will select the TDS sections that are within this distance. <br/>
KvbTpsToTargetRelation
Class  
Name: hasDistanceTpsToTarget
 
Name:  
 
Details:
Distance from the TP device to the target. Can be zero.<br/>fr-FR: distance but<br/>
VerticalSegmentTransition
Class  
Name: finalRadius
 
Name:  
 
Details:
The radius of the circle tangential to the end of the segment.<br/>Start and end with respect to the orientation of the linear element of the topology that carries the segment.<br/>
SafetyDistance
Class  
Name: hasMinimalLength
 
Name:  
 
Details:
Minimal length of the safety distance, measured from the route exit signal.<br/>
HorizontalAlignmentSegment
Class  
Name: length
 
Name:  
 
Details:
The length of the segment when projected on the horizontal plane. The length is optional because it may be irrelevant or may be derived from position information associated with the linear location. <br/>
CombiningTrack
Class  
Name: hasUsefulLength
 
Name:  
 
Details:
The length of the track that can actually be used for coupling trains under nominal conditions.<br/>
Cable
Class  
Name: hasLength
 
Name:  
 
Details:
In situ required or designed length of cable. <br/>Can differ from the length of cable route because of the need to cover the last metres to the field element, slack or spare length.<br/>
BarrierBoom
Class  
Name: length
 
Name:  
 
Details:
Required boom length as manufactured and ordered. <br/>The boom may be shortened on site (DB). <br/>Must concur with the full/half type of boom (if given).<br/>
LinearPositioningSystem
Class  
Name: endMeasure
the highest abscissa in this system.
Name:  
 
Details:
The highest value of the abscissa in this system. <br/>
Canvas
Class  
Name: height
 
Name:  
 
Details:
height of the canvas in a given unit, e.g. mm or pixel<br/>
LevelCrossingSignalRelation
Class  
Name: hasDistanceToTrackCrossingBorder
 
Name:  
 
Details:
The distance between the protecting main signal and the edge of the crossing path or road.<br/>
TpsDeviceProperties
Class  
Name: hasLength
 
Name:  
 
Details:
e.g. length of infill loop. <br/>Balises, magnets, crocodiles or TPWS loops are considered point devices without a length.<br/>
KvbRelation
Class  
Name: hasDistanceFromTpsToFoulingPoint
 
Name:  
 
Details:
fr-FR: distance balise au garage franc, utilisée pour un point prox avec distance de glissement inférieure à 50m.<br/>
HorizontalSegmentTransition
Class  
Name: initialRadius
 
Name:  
 
Details:
The radius of the circle tangential to the beginning of the segment.<br/>Start and end with respect to the orientation of the linear element of the topology that carries the segment.<br/>
RoadTrafficSign
Class  
Name: hasDistanceToPathEdge
 
Name:  
 
Details:
The distance between the traffic sign and the nearest edge of the road or path to which the sign applies.<br/>
LateralDistance
Class  
Name: distance
 
Name:  
 
Details:
 
RoadTrafficLightProperties
Class  
Name: hasOpticsDiameter
 
Name:  
 
Details:
The diameter of the optical disc.<br/>Only given when relevant.<br/>de-DE: Durchmesser der Signalgeberoptik<br/>
Element Source Role Target Role
AlignmentCantSegment
Class  
Name:  
 
Name: length
 
Details:
 
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
LC-2326 - Clearing distance DAB Requirement Dependency From  
PresignProperties Class Strong To de-DE: Räumstrecke dSK' gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).
CircularTurnout Class Strong To  
VerticalSegmentTransition Class Strong To The radius of the circle tangential to the beginning of the segment. Start and end with respect to the orientation of the linear element of the topology that carries the segment.
SignalSightingDistance Class Strong To Minimal distance calculated based on the minimum response time, the signal complexity and the local speed. Fixed in national rules, sometimes adapted to local circumstances.
GE-1315 - Line meter Requirement Dependency From  
LinearCoordinate Class Strong To Lateral offset. The sign is always positive and the side, left or right, is given by the spot location's lateral side.
FtgsTrackCircuitProperties Class Strong To Electric length of FTGS subsection E1, E2, E3 (See the FTG S documentation).
LB-0203 - Breaking distance Requirement Dependency From  
TD-0611 - TDS length section E1 Requirement Dependency From  
LC-2210 - Supplied length Requirement Dependency From  
PresignProperties Class Strong To de-DE: Räumstrecke dCK gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).
LinearCoordinate Class Strong To Distance from the anchor point.
AnchorPoint Class Strong To The measure value of the anchor point, e.g. km 47.5 ISO19148:2021 uses the term "RestartValue".
TpsRelation Class Strong To Required distance from the TP device or system to the signal.
VerticalAlignmentSegment Class Strong To The length of the segment when projected on the vertical surface. The length is optional because it may be irrelevant or may be derived from position information associated with the linear location.
SignalAlignmentPointOnTrack Class Strong To height over the track of the alignment target
SignalAlignmentPointOnTrack Class Strong To distance along the track to the alignment target
TpwsTrainCategorySpecificProperties Class Strong To  
ZbsReducedSpeedProperties Class Strong To Distance between BG and start of reduced speed section. de-DE: Distanz zwischen Datenpunkt und Beginn der Geschwindigkeitseinschränkung.
TP-0810 - Speed checking system measuring section Requirement Dependency From  
HorizontalSegmentArc Class Strong To Radius of the arc.
TD-0614 - TDS length section S Requirement Dependency From  
PresignProperties Class Strong To de-DE: Räumstrecke dBK gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).
ElementLength Class Abstraction From Element length is an observable property; it is therefore linked with a source (specification, measurement...) and provides a length. See also Observation and Measure package.
SignalSightingDistance Class Strong To Reading distance with the help of mitigation works, e.g. removing obstruction by foliage.
LC-2327 - Clearing distance DBK Requirement Dependency From  
LevelCrossingSignalRelation Class Strong To The distance between signal/sign and track crossing centre.
SignalSightingDistance Class Strong To Smallest distance where the signal can be read. Closer to the signal, the driver may not be able to view the signal.
TpsProtectionDistance Class Strong To The value of the TPS protection distance.
GE-0105 - Cant heigth Requirement Dependency From  
ChangeMarker Class Strong To The distance over which the change applies.
SignalSightingDistance Class Strong To Reading distance without any mitigation works, i.e. assessed on site before removing obstructions. Applies either to a signal or to individual signal frame.
TD-0612 - TDS length section E2 Requirement Dependency From  
SI-0424 - DistanceToAWSMagnet Requirement Dependency From  
LC-0812 - Protection distance Requirement Dependency From  
GE-0802 - GEO radius A Requirement Dependency From  
LC-2214 - Distance to path Requirement Dependency From  
OffsetOfReferencePoint Class Strong To The offset of the reference point with respect to:
  • the nearest rail (SNCF, NR).
  • the centre line of the track (DB).
KvbTpsToTargetRelation Class Strong To Distance between signal and target. fr-FR: distance entre signal et point but. Utilisée pour balise prox à distance de glissement entre 100m et 200m.
EtcsRouteApproachLocking Class Strong To The distance for long range timeless revocation of the approach route. A train that is closer than this distance must cooperate in revoking the MA.
LxDepartureDetection Class Strong To The distance over which the restricted speed applies. This allows the LX sufficient time to close.
LC-2331 - Blocking distance pedestrians Requirement Dependency From  
AnchorPoint Class Strong To  
LowFrequencyTrackCircuitProperties Class Strong To Influenced length for track circuit using the NF technology.
RoadTrafficLightProperties Class Strong To de-DE: Sperrstrecke als Abstand Lz/Andreaskreuz - gegenüberliegende Schranke (dF). Die Angabe ist nur bei beschrankten Bahnübergängen erforderlich.
TpsDataTransmissionSystemProperties Class Strong To The (positive) length over which a TP System extends. For instance: length of a balise group from first to last in group.
ProjectedLength Class Generalization From  
Canvas Class Strong To Width of the canvas in a given unit (e.g. mm or pixel) if not implied in the canvas name.
Cant Class Strong To The height difference between the outer and inner rails in or in approach to a curve. The value is normally positive. It is negative in the exceptional case when the inner rail is higher. Corresponds to IFC4.3 IfcAlignmentCant attribute RailHeadDistance.
LineBlockInformation Class Strong To The block line is designed for the given braking distance. Only used by DB for validation purposes. de-DE: Bremsweg als Grundlage für die Dimensionierung der zugehörigen Strecke. SNCF documents show the signals and the distances between signals, ergo no need for braking distance parameter.
LocalReference Class Strong To Distance from the referenced location (positive number). en-UK: set out distance
EtcsSignalProperties Class Strong To The shortest overlap in the category less than 50 metres. Only given when the interlocking can't dynamically provide the overlap length to the RBC.
BaliseGroupPurpose Class Strong To The distance to the track asset that justifies the presence of the balise group.
RoadTrafficLightProperties Class Strong To de-DE: Sperrstrecke als Abstand Lz/Andreaskreuz - gegenüberliegende Gefahrraumgrenze (d). Die Angabe ist nur bei unbeschrankten Bahnübergängen erforderlich.
RoadTrafficLightProperties Class Strong To de-DE: Angaben zur Sperrstrecke bei BÜ der Art LzH bzw. LzHH. Teilsperrstrecke als Abstand Lz - Schranke (d1).
SignalSightingDistance Class Strong To Combined reading distance for the signal and any associated repeaters.
TD-0610 - TDS length influenced Requirement Dependency From  
TD-0609 - TDS length Requirement Dependency From  
PredefinedZbsTelegramSet Class Strong To Safety distance that is needed beyond the target signal, given the release speed. de-DE: Erforderliche Schutzstrecke; hinter dem Zielsignal des Überwachungsabschnitts für die gewählte Freigabegeschwindigkeit geforderte Soll-Länge der Schutzstrecke.
LC-1408 - Roadway width Requirement Dependency From  
EtcsConditionalEmergencyStopMarker Class Strong To The CES can be shifted by a (positive) offset, always in rear of the signal.
BarrierBoom Class Strong To The span of roadway and pathway that is blocked by the lowered boom. de-DE: Sperrlaenge
PredefinedEtcsTelegramSetTilting Class Strong To Target distance up to the start of the section of reduced speed. de-DE: Zielentfernung bis zum Beginn des La-Bereichs.
LC-2329 - Clearing distance DSK dash Requirement Dependency From  
SignalSightingDistance Class Strong To Distance at which the signal shall be visible if economically viable. Fixed in national rules. Always greater than the minimum distance.
  • For NR this maps to "required distance" and can also apply to the route indicators or shunting aspects.
  • de-DE: Sollsignalsicht.
OT-0503 - Value Requirement Dependency From  
KvbTpsToTargetRelation Class Strong To Distance from target to fouling point. fr-FR: distance entre point but et garage franc. Utilisée pour balise prox à distance de glissement entre 50m et 100m.
PathCrossingProperties Class Strong To Width of an additional cycle or foot path that is adjacent to the main carriage way.
TpMarker Class Strong To The change must have been completed with this distance (counting from the marker). Also known as transition length. This length would normally be calculated by design rules, derived from time/max speed, and can be recorded here for validation purposes.
PlatformEdge Class Strong To Height over nearest rail. Can be specialised in national domain if a national list of allowed heights applies.
CentralControlledAreaDepartureTrack Class Strong To Length of track that departing trains can use.
VerticalSegmentArc Class Strong To Radius of the arc.
EtcsEndOfAuthority Class Strong To The ETCS EoA is located at a given distance in rear of the signal.
TrackCrossingProperties Class Strong To Width of the road/way that crosses the railway track. The width measure is governed by national rules. NR includes any cycle or foot path in the measure.
LinearPositioningSystem Class Strong To The lowest value of the abscissa in the positioning system.
SandHump Class Strong To  
OT-0503 - Value Requirement Dependency From  
EtcsRouteApproachLocking Class Strong To The distance in approach to the signal where no route cancellation for trains in SR is possible.
SpecialTrackGauge Class Strong To Dual gauge has two values for the distance between the rails, e.g. in CH.
NumericQuantity Class Generalization To  
ThreeDLength Class Generalization From  
LC-2330 - Blocking distance Requirement Dependency From  
LC-2328 - Clearing distance DCK Requirement Dependency From  
PredefinedZbsTelegramSet Class Strong To The safety distance that is actually available beyond the target signal of the supervised section. de-DE: Vorhandene Schutzstrecke; hinter dem Zielsignal des Überwachungsabschnitts vorhandene Ist-Länge der Schutzstrecke.
RoadTrafficLightProperties Class Strong To de-DE: Angaben zur Sperrstrecke bei BÜ der Art LzH bzw. LzHH. Räumstrecke als Abstand Schranke - gegenüberliegende Gefahrraumgrenze (d2).
PredefinedEtcsTelegramSetTilting Class Strong To length of reduced speed section de-DE: Länge des La-Bereichs.
LC-2334 - Partial blocking distance Requirement Dependency From  
BarrierMechanism Class Strong To Distance between the barrier mechanism and the nearest edge of footway or carriageway that the barrier boom protects. Only stored if relevant.
EpsSignalProperties Class Strong To Given only when this signal protects a tunnel entry. The tunnel then has the given length.
CA-0105 - Cable length Requirement Dependency From  
SpeedCheckingSystemProperties Class Strong To Distance between two speed checking devices, also known as trip distance. NR: speed checking length maps to OSS spacing
OT-0502 - Units Requirement Dependency From  
LinearCoordinate Class Strong To Vertical offset. Can be positive or negative.
HorizontalSegmentTransition Class Strong To Radius at the end of the segment.
PresignProperties Class Strong To de-DE: Räumstrecke dAB gemäß Ril 815.0033A01 (vorgeschaltete Lichtzeichen).
BaliseGroupLinking Class Strong To Distance between from-to balise groups (N_PIG=0)
PredefinedZbsTelegramSet Class Strong To Length of the supervised section. de-DE: Länge des Überwachungsabschnitts.
EtcsSignalProperties Class Strong To The shortest overlap in the category 50 to less than 200m. Only given when the interlocking can't dynamically provide the overlap length to the RBC.
EtcsSignalProperties Class Strong To Shortest overlap in the category 200m and upwards. Only given when the interlocking can't dynamically provide the overlap length to the RBC.
EtcsLevelTransitionMarker Class Strong To Maximum train length for which the level transition is designed. de-DE: Max. Zuglänge für die Berechnung der Ausdehnung von Bereich "C".
TrackCircuitProperties Class Strong To Electric length of the section, computed according to the regulations and the local particularities.
FtgsTrackCircuitProperties Class Strong To Electric length of FTGS subsection S (See the FTG S documentation).
ZbsReducedSpeedProperties Class Strong To Length of the reduced speed section. de-DE: Länge des Bereichs der Geschwindigkeitseinschränkung.
LC-2318 - Optics diameter Requirement Dependency From  
LC-2104 - Mounting height Requirement Dependency From  
LC-2212 - Prevents passage over length Requirement Dependency From  
RadarReflector Class Strong To The height over the ground level at which the reflector is mounted.
RouteApproachLocking Class Strong To The distance in approach to the signal that is required for the approach locking. Typically the designer will select the TDS sections that are within this distance.
TD-0613 - TDS length section E3 Requirement Dependency From  
KvbTpsToTargetRelation Class Strong To Distance from the TP device to the target. Can be zero. fr-FR: distance but
VerticalSegmentTransition Class Strong To The radius of the circle tangential to the end of the segment. Start and end with respect to the orientation of the linear element of the topology that carries the segment.
GE-0804 - GEO azimuth Requirement Dependency From  
SafetyDistance Class Strong To Minimal length of the safety distance, measured from the route exit signal.
LC-2306 - Distance to path Requirement Dependency From  
HorizontalAlignmentSegment Class Strong To The length of the segment when projected on the horizontal plane. The length is optional because it may be irrelevant or may be derived from position information associated with the linear location.
CombiningTrack Class Strong To The length of the track that can actually be used for coupling trains under nominal conditions.
Cable Class Strong To In situ required or designed length of cable. Can differ from the length of cable route because of the need to cover the last metres to the field element, slack or spare length.
BarrierBoom Class Strong To Required boom length as manufactured and ordered. The boom may be shortened on site (DB). Must concur with the full/half type of boom (if given).
GE-0803 - GEO radius B Requirement Dependency From  
TP-0804 - Intermittent train protection distance to signal Requirement Dependency From  
LC-2333 - Clearing distance Requirement Dependency From  
LinearPositioningSystem Class Strong To The highest value of the abscissa in this system.
Canvas Class Strong To height of the canvas in a given unit, e.g. mm or pixel
LevelCrossingSignalRelation Class Strong To The distance between the protecting main signal and the edge of the crossing path or road.
TpsDeviceProperties Class Strong To e.g. length of infill loop. Balises, magnets, crocodiles or TPWS loops are considered point devices without a length.
RO-0504 - Minimum overlap length Requirement Dependency From  
TP-0807 - Speed checking system distance divergent Requirement Dependency From  
KvbRelation Class Strong To fr-FR: distance balise au garage franc, utilisée pour un point prox avec distance de glissement inférieure à 50m.
HorizontalSegmentTransition Class Strong To The radius of the circle tangential to the beginning of the segment. Start and end with respect to the orientation of the linear element of the topology that carries the segment.
RoadTrafficSign Class Strong To The distance between the traffic sign and the nearest edge of the road or path to which the sign applies.
LateralDistance Class Strong To  
RoadTrafficLightProperties Class Strong To The diameter of the optical disc. Only given when relevant. de-DE: Durchmesser der Signalgeberoptik