| Created: | 02.03.2020 14:10:30 |
| Modified: | 14.12.2021 16:52:02 |
Project: |
|
Advanced: |
|
| Element | Source Role | Target Role |
|
DiscretisedPoint Class |
Name: hasSpotLocation |
Name: |
Details:
Allows to document the location in one or more reference system(s).<br/><br/>
|
||
|
PositioningSystemCoordinate Class |
Name: |
Name: coordinates |
Details:
The spot location is positioned in a given coordinate reference system that is typically independent of the network topology.<br/>
|
||
| Element | Source Role | Target Role |
|
Gate Class |
Name: |
Name: isLocatedAt |
Details:
The location of the gate's hinge.<br/>
|
||
|
BarrierMechanism Class |
Name: |
Name: isLocatedAt |
Details:
The barrier mechanism is located at this spot location. <br/>The spot location's application direction is undefined (use quadrant and angle instead).<br/>
|
||
|
SwitchGear Class |
Name: |
Name: isLocatedAt |
Details:
The location of the connection point.<br/>
|
||
|
EtcsOverlap Class |
Name: |
Name: hasTimerStartLocation |
Details:
The location of the timer start is at a distance of D_STARTOL in rear of the EoA.<br/>
|
||
|
Transformer Class |
Name: |
Name: connectsAt |
Details:
Spot location where the transformer connects to the track.<br/>
|
||
|
Cant Class |
Name: |
Name: isLocatedAt |
Details:
A spot location where the cant applies.<br/>
|
||
|
Telephone Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
InfrastructureBorder Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
EquipmentSupport Class |
Name: |
Name: isLocatedAt |
Details:
Complex equipment supports may have multiple spot locations, e.g. a gantry with two foundations on each side of the track. The gantry can also support multiple signals, each with its own spot location. <br/><br/>
|
||
|
LineSideSpotSystem Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
OffsetOfReferencePoint Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
TcFeederReceiverElement Class |
Name: |
Name: isLocatedAt |
Details:
The spot location of the feeder/receiver; typically near but not necessarily exactly at the section limit.<br/>
|
||
|
LevelCrossingKeyBox Class |
Name: |
Name: isLocatedAt |
Details:
The key box is located at the given spot location.<br/>
|
||
|
MovableElement Class |
Name: |
Name: hasClearancePointLocatedAt |
Details:
|
||
|
LevelCrossingConfiguration Class |
Name: |
Name: hasBatteryLocatedAt |
Details:
The level crossing system is fitted with a battery that is located at the given location.<br/>
|
||
|
Mechanism Class |
Name: |
Name: isLocatedAt |
Details:
Individual components of a turnout and its movable elements can be spot-located.<br/>
|
||
|
AccessPoint Class |
Name: |
Name: isLocatedAt |
Details:
The spot location links to the linear element, i.e. the track, and coordinates, and chainage.<br/>
|
||
|
ChangeMarker Class |
Name: |
Name: appliesFrom |
Details:
Applies from this spot location and works in the application direction.<br/>
|
||
|
ElevationAndInclination Class |
Name: |
Name: isLocatedAt |
Details:
The spot location, including an elevation.<br/>
|
||
|
EtcsMaSection Class |
Name: |
Name: hasTimerStartLocation |
Details:
The spot location where the section timer starts counting down. <br/>
|
||
|
WarningSystem Class |
Name: |
Name: isLocatedAt |
Details:
Allows spot locating the warning system (optional addition to locating the individual components)<br/>
|
||
|
LocationOfInterest Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
Diamond Class |
Name: |
Name: isLocatedAt |
Details:
The diamond is spot-located where the two linear net elements cross.<br/>
|
||
|
ImpedanceBond Class |
Name: |
Name: isLocatedAt |
Details:
The impedance bond is spot-located on or beside the line.<br/>
|
||
|
Crossing Class |
Name: |
Name: crossingCentre |
Details:
The spot location where the tracks physically intersect.<br/>
|
||
|
TrackCrossing Class |
Name: |
Name: hasCrossingPathBorder |
Details:
The location of the point on the centre of the track where the road/path starts. Needed in case of a track crossing that is protected by an interlocking-integrated level crossing.<br/>DB: BÜ-Kante. <br/>
|
||
|
AnchorPoint Class |
Name: |
Name: isLocatedAt |
Details:
Informs the spot location of the anchor point.<br/>
|
||
|
LocatedMovableComponent Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
TimingPoint Class |
Name: |
Name: isLocatedAt |
Details:
Reference to the location of the timing point.<br/>
|
||
|
PlatformNonStoppingLocation Class |
Name: |
Name: isLocatedAt |
Details:
The spot location of the platform clearance point (TAV).<br/>
|
||
|
AssociatedNetElement Class |
Name: associatedNetElements |
Name: |
Details:
Associates the location with net element(s).<br/>
|
||
|
MovableElement Class |
Name: |
Name: hasFoulingPointLocatedAt |
Details:
The fouling point is a spot location. It is located with respect to the track(s) that are fouling.<br/>A decommissioned point may have no fouling point.<br/>
|
||
|
TcConnector Class |
Name: |
Name: isConnectedToRailAt |
Details:
Describes where the TcConnector (or Cable) is connected to the rail, not the dimensions of the connector itself.<br/>
|
||
|
Node Class |
Name: |
Name: isLocatedOnTrackTopology |
Details:
A node can be defined as spot location on the track topology.<br/>
|
||
|
DispatchPosition Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
PowerLineCrossing Class |
Name: |
Name: crossesTrackAt |
Details:
A power line can cross one or more tracks at the given location.<br/>
|
||
|
EtcsMaSection Class |
Name: |
Name: hasTimerStopLocation |
Details:
The spot location where the section timer is stopped (§3.8.4.2.3).<br/>
|
||
|
NonStoppingPoint Class |
Name: |
Name: clearsLocation |
Details:
The location that trains must or should clear<br/>
|
||
|
Floodlight Class |
Name: |
Name: isLocatedAt |
Details:
The headlight is located at the given spot location.<br/>
|
||
|
EtcsMaSection Class |
Name: |
Name: hasSectionEntryLocation |
Details:
Entry to the MA section. This spot location will typically be the location of a balise that <i>can</i> serve as LRBG (L2 MA) or the balise that emits the MA (L1 MA).<br/>
|
||
|
TrackCrossing Class |
Name: |
Name: isLocatedAt |
Details:
The spot location where the decking and the rail tracks cross.<br/>There can be multiple locations because more than one rail track can be crossed.<br/>
|
||
|
TrainDescriberSubstation Class |
Name: |
Name: hasDrawingLocation |
Details:
Spot location; paper coordinates for the purpose of plotting a scheme plan - not a geographical position.<br/>de-DE: Positionierung der ZN-Unterstation(en) auf dem ZLV-Bus-Übersichtsplan.<br/>
|
||
|
TpsDataTransmissionSystem Class |
Name: |
Name: isLocatedAt |
Details:
The location of the system. The spot location includes an application direction with respect to the associated linear net element.<br/>
|
||
|
TrafficFlow Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
TractionFeed Class |
Name: |
Name: isLocatedAt |
Details:
The location of the connection point.<br/>
|
||
|
PlatformEdgeAccessPoint Class |
Name: |
Name: isLocatedAt |
Details:
The location of the platform access point, projected on the platform edge.<br/>
|
||
|
StoppingPoint Class |
Name: |
Name: isLocatedAt |
Details:
The stopping point location for trains arriving in the direction given by the spot location's application direction. <br/>
|
||
|
LxDepartureDetection Class |
Name: |
Name: hasDepartureDetectionPoint |
Details:
The spot up to where ETCS train departure detection can activate the level crossing.<br/>
|
||
|
Turnout Class |
Name: |
Name: origin |
Details:
Origin is spot location of the tangent or secant point where the diverted track meets the through track. Origin coincides with the ends of the topological elements.<br/>
|
||
|
RadarReflector Class |
Name: |
Name: isLocatedAt |
Details:
|
||
|
ExpansionJoint Class |
Name: |
Name: isLocatedAt |
Details:
|
||
| Property | Value |
| isFinalSpecialization: | 0 |
| Object | Type | Connection | Direction | Notes |
| LC-1225 - Location | Requirement | Dependency | From | |
| LockingDevice | Class | Dependency | From | The device links to housing which provides the spot location. |
| Elevation | Class | Dependency | To | The spot location includes an elevation. |
| LC-1221 - Location | Requirement | Dependency | From | |
| BaseLocation | Class | Generalization | To | |
| LC-17 - LC crossing path border | Requirement | Dependency | From | |
| TS-1120 - ID GEO point | Requirement | Dependency | From | |
| DiscretisedPoint | Class | Strong | To | Allows to document the location in one or more reference system(s). |
| TpsDevice | Class | Dependency | From | The spot location of the device is provided by the TpsDevice in the RSM namespace. TPS devices have either a spot or a linear location. |
| GE-1622 - Position | Requirement | Dependency | From | |
| LC-1233 - Location | Requirement | Dependency | From | |
| GE-1623 - Direction | Requirement | Dependency | From | |
| OT-1801 - Location | Requirement | Dependency | From | |
| AssociatedNetElement | Class | Strong | From | Associates the location with net element(s). |
| LC-1237 - Location | Requirement | Dependency | From | |
| OT-1910 - View | Requirement | Dependency | From | |
| LC-1203 - Location | Requirement | Dependency | From | |
| LC-1229 - Location | Requirement | Dependency | From | |
| TimedLocation | Class | Generalization | From | |
| LC-1210 - Location | Requirement | Dependency | From | |
| GE-0824 - Position | Requirement | Dependency | From | |
| GE-0825 - Direction | Requirement | Dependency | From | |
| TD-0661 - TDS insulation type | Requirement | Dependency | From |