TC Connector : Public abstract Class
A connector used by track circuits.<br/>
- Attributes
- Associations To
- Associations From
- Advanced
- Other Links
Attribute |
Private string cableType
|
Details:
Alias: |
Cable Type |
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
|
Transient: |
False |
Derived: |
False |
IsID: |
False |
Notes:
|
Description of the type of cable according to cable book. For instance:<br/><ul> <li>DE: 120 Cu, 240 Al. </li><li>UK: cable type 5.</li><li>NL: kabel 50 mm2 koper of 70 mm2 aluminium.</li></ul><p/>
|
|
Private int numberOfStrands
|
Details:
Alias: |
Number of Strands |
Initial: |
|
Stereotype: |
|
Ordered: |
|
Range: |
Range:0 to 1 |
Transient: |
False |
Derived: |
False |
IsID: |
False |
Notes:
|
Number of strands in a cable. <br/>Used in DE.<br/>DE: Verdrillte Seilen. <br/>NL: aantal aders.<br/>
|
|
Element |
Source Role |
Target Role |
SpotLocation
Class
|
Name:
|
Name: isConnectedToRailAt
|
 Details:
Describes where the TcConnector (or Cable) is connected to the rail, not the dimensions of the connector itself.<br/>
|
Element |
Source Role |
Target Role |
LeftRight
Enumeration
|
Name: connectsToRail
|
Name:
|
 Details:
Denotes to which rail to connect. Given with respect to the orientation of the topological linear element.<br/>
|
Property |
Value |
isFinalSpecialization: |
0 |