| Element | Source Role | Target Role |
|
ControlArea Class |
Name: |
Name: controlsArea |
Details:
Expresses that the housing, a proxy for the controllers in that housing, is in charge of a given area.<br/>NR: Early engineering links housing to control area. The latter lists the controlled items.<br/>
|
||
| Element | Source Role | Target Role |
|
Controller Class |
Name: |
Name: isHousedIn |
Details:
|
||
|
TechnicalCentre Class |
Name: |
Name: isHousedIn |
Details:
The technical centre is housed in a building, an equipment room or container.<br/>
|
||
|
ElectricProperties Class |
Name: hasElectricProperties |
Name: |
Details:
The housing needs a power supply with the given electric rating.<br/>
|
||
|
TrDrSubstationWithGateway Class |
Name: |
Name: isHousedIn |
Details:
The gateway communication housing, e.g. a dedicated communication room in the central interlocking building. <br/>
|
||
|
CableRouteJunctionNode Class |
Name: |
Name: joinsHousing |
Details:
The housing on the cable route or where the cable route terminates.<br/>
|
||
|
PhysicalPowerSupplyModule Class |
Name: |
Name: isHousedIn |
Details:
The housing of the power supply module. Typically but not necessarily, a LEU cabinet.<br/>
|
||
|
TrainDescriberSystem Class |
Name: |
Name: isHousedIn |
Details:
Refers to the housing of the train describer system, typically the computer room that also houses the central interlocking system. <br/>de-DE: Verweis auf den physischen Ort der Unterbringung.<br/>
|
||
|
TpsDataTransmissionSystem Class |
Name: |
Name: hasControllerHousedIn |
Details:
A speed checking system controller can have a line side housing. Not suited for LEU housing. <br/>
|
||
|
CableJointInstallation Class |
Name: |
Name: isHousedIn |
Details:
The housing of the cable joint installation tends to dictate which class to use. The function is always the same, i.e. joining, terminating cables and wires.<br/>A cable termination rack is housed in the IL room or in a cabinet in the IL room.<br/>
|
||
|
IpAddressAssignment Class |
Name: |
Name: appliesToHousing |
Details:
The collection of IP addresses is assigned to this housing.<br/>
|
||
|
LockingDevice Class |
Name: |
Name: isHousedIn |
Details:
|
||
|
LockCombination Class |
Name: |
Name: isHousedIn |
Details:
|
||
|
PhysicalMdm Class |
Name: |
Name: isHousedIn |
Details:
|
||
|
FixingTypes Enumeration |
Name: isSupportedByFixingType |
Name: |
Details:
|
||
|
PointHandle Class |
Name: |
Name: isHousedIn |
Details:
Reference to the housing, typically a cabinet, where equipment is stored. Housing is spot-located.<br/>
|
||
|
CommunicationNode Class |
Name: |
Name: appliesToHousing |
Details:
|
||
|
OperatingCentre Class |
Name: |
Name: isHousedIn |
Details:
|
||
| Property | Value |
| isFinalSpecialization: | 0 |
| Object | Type | Connection | Direction | Notes |
| OC-0825 - ControlledItems | Requirement | Realization | To | |
| OC-0804 - Housing general attributes | Requirement | Realization | To | |
| OC-0807 - Housing fixing | Requirement | Realization | To | |
| OC-0711 - ID Housing | Requirement | Realization | To | |
| CA-0403 - ID Connected element | Requirement | Realization | To | |
| ElectricProperties | Class | Strong | From | The housing needs a power supply with the given electric rating. |
| EquipmentSupport | Class | Generalization | To | |
| CA-0203 - ID Housing | Requirement | Realization | To | |
| LD-0404 - ID Housing | Requirement | Realization | To | |
| OC-0523 - OperatorPosition | Requirement | Realization | To | |
| Container | Class | Generalization | From | |
| EquipmentRoom | Class | Generalization | From | |
| FixingTypes | Enumeration | Strong | From | |
| OC-0815 - Position description | Requirement | Realization | To | see attribute position description |
| TP-0814 - ID Housing | Requirement | Realization | To | |
| Box | Class | Generalization | From | |
| OC-0903 - ID Housing | Requirement | Realization | To | |
| OC-0806 - Housing type | Requirement | Realization | To | |
| NoHousing | Class | Generalization | From | |
| OC-0828 - ControlledItems | Requirement | Realization | To | |
| Panel | Class | Generalization | From | |
| OC-08 - Housing | Requirement | Realization | To | |
| TS-1204 - ID Housing | Requirement | Realization | To | |
| Cabinet | Class | Generalization | From | |
| LeuCabinet | Class | Dependency | From | Mostly, the power supply module is inside the LEU cabinet which is a housing. |
| Building | Class | Generalization | From | |
| TS-1313 - ID Interlocking central unit | Requirement | Realization | To | |
| LD-0303 - ID Housing | Requirement | Realization | To |