Signal Aspect Degradation : Public Class
Created: 11.02.2020 13:47:59
Modified: 11.11.2021 14:11:45
Project:
Advanced:
Provides signal aspect degradation information that is associated with a given light signal.<br/>
Attribute
Private boolean
  isMostRestrictive
Details:
Notes: True: the active aspect set is the most restrictive that the signal shows:<br/><ul>
<li>when not controlled by the interlocking, e.g. in case of failed communication between interlocking and signal controller.</li><li>during system start.</li></ul>
False: degrade to the given set of active aspects.<br/>
Element Source Role Target Role
ActiveAspect
Class  
Name:  
 
Name: appliesWhenAspectFails
 
Details:
When this given active aspect fails, degrade to the given active aspect set.<br/>
LightSignal
Class  
Name:  
 
Name: appliesToLightSignal
 
Details:
The signal to which the degradation stepping applies.<br/>If no signal is given, the aspect degradation class is a template that can be stored in a file and be applied to signals in particular projects.<br/>
ActiveAspectSet
Class  
Name:  
 
Name: degradesToActiveAspectSet
 
Details:
The active aspect set shown when the commanded set of active aspects can't be shown.<br/>
ActiveAspectSet
Class  
Name:  
 
Name: appliesToActiveAspectSet
 
Details:
Applies to this set of active aspects.<br/>
DataPrepEntities
Class  
Name: ownsSignalAspectDegradation
 
Name:  
 
Details:
 
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
Byte 50 route information ? Issue Dependency To  
ConfiguredBaseObject Class Generalization To  
Eu.LS.6091 Requirement Realization To  
DataPrepEntities Class Strong To