Identifier of senders and receivers of telegrams. A technical identifier uniquely identifies a EULYNX subsystem or an adjacent system.<br/>The schema is [country code][area designator][system type][code][tag][sequence no]<br/>E.g. A Subsystem - Generic IO 5 in Germany in area HG2_X in operating location 37 has the identifier: DEHG2_XIO___37##0005.<br/>Also known as SubS_ID. <br/>
Attribute
Private string
  areaCode
Details:
Notes: Area designator: 5 characters ISO IEC 8859-1:1998, left justified, empty space to be filled with underscore (0x5F)<br/>
Private string
  code
Details:
Notes: A two-character string ISO IEC 8859-1:1998, in the range "0"-"9".<br/>E.g.  "07"  or  "23"<br/>
Private string
  countryCode
Details:
Notes: Country code as two bytes.<br/>Recommended is ISO-3166, e.g. NL, FR, CH, GB.<br/>This is a two  character string (ISO IEC 8859-1:1998, left justified).<br/>
Private string
  sequenceNumber
Details:
Notes: 4 characters ISO IEC 8859-1:1998 in the range '0'-'9' decimal, empty spaces filled with "0"<br/>
Private string
  systemType
Details:
Notes: 5 characters ISO IEC 8859-1:1998, left justified, empty space to be filled with underscore (0x5F), as per list below:<br/>The following system types are to be used:<br/>LS Subsystem - Light Signal<br/>P Subsystem - Point<br/>TDS Subsystem - Train Detection System<br/>IO Subsystem - Generic IO<br/>LC Subsystem - Level Crossing<br/>EIL Subsystem - Electronic Interlocking<br/>MDM Subsystem - Maintenance and Data Management<br/>TCS adjacent system Traffic Control System<br/>RBC adjacent system Radio Block Centre<br/>TSS adjacent system Trackworker Safety System<br/>CEC adjacent system Centralised ETCS L1 Controller<br/>LX adjacent system External Level Crossing System<br/>Note: The scope of the adjacent system Traffic Control System shall be defined by national requirements. It shall be possible to add additional<br/>system types to cover subsystems of the Traffic Control System.<br/>
Private string
  tag
Details:
Notes: 2 characters ISO IEC 8859-1:1998, fixed "##"<br/>
Element Source Role Target Role
MaintenanceDataManagement
Class  
Name: hasEulynxTechId
 
Name:  
 
Details:
This MDM has a EULYNX technical identifier.<br/>
WarningSystem
Class  
Name: technicalIdentifier
 
Name:  
 
Details:
 
Controller
Class  
Name: hasEulynxTechId
 
Name:  
 
Details:
This controller has a EULYNX technical identifier.This is mandatory for EULYNX subsystems.<br/>
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
Eu.SAS.1756 Requirement Realization To  
Eu.SAS.74 Requirement Realization To  
MaintenanceDataManagement Class Strong To This MDM has a EULYNX technical identifier.
Eu.SAS.2016 Requirement Realization To  
Designation Class Dependency To  
Eu.SAS.77 Requirement Realization To  
BaseObject Class Generalization To  
WarningSystem Class Strong To  
describe mapping rule Issue Dependency To  
Eu.SMI.233 Requirement Realization To  
Controller Class Strong To This controller has a EULYNX technical identifier.This is mandatory for EULYNX subsystems.